2
Mount sensors (sender and receiver) using suitable mounting brackets (see the
SICK range of accessories). Align the sender and receiver with each other.
Note the sensor's maximum permissible tightening torque of 0.6 Nm.
3
The sensors must be connected in a voltage-free state (V
S
= 0 V). The information
in the graphics [B] must be observed, depending on the type of connection:
–
Male connector connection: pin assignment
–
Cable: core color
Image: B
Only apply voltage / switch on the power supply (V
S
> 0 V) once all electrical con‐
nections have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (graphic B):
Switching outputs Q and /Q (according to graphic B):
WSE9(M4)-3P (PNP: load -> M)
WSE9(M4)-3N (NPN: load -> L+)
TE / Test = test input (see Additional functions)
4
Align the sender with the receiver. Select the position so that the red emitted light
beam hits the receiver. Tip: Use white paper or a reflector as an alignment aid. The
sender must have a clear view of the receiver, with no object in the path of the be‐
am [see E]. You must ensure that the optical openings (front screen) of the sensors
are completely clear.
3
COMMISSIONING
2
8017641 | SICK