Table 3: DC, receiver
WEO16 -24165x
xxA00
-34165x
xxA00
-1x65xxx
A00
-24163x
xxA00
-34163x
xxA00
-1x163xx
xA00
-24166x
xxA00
-34166x
xxA00
-1x166xx
xA00
-24164x
xxA00
-34164x
xxA00
-1x164x
xxA00
1
+ (L+)
2
MF
3
- (M)
4
Q
L1
/C
Default:
MF
Alarm
Alarm
Alarm
Alarm
Health
Health
Health
Health
Default:
Q
L1
/C
Q
Q
Q
Q
Q
Q
Q
Q
1
2
4
3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
1
2
4
3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
1
2
4
3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
1
2
4
3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 m
m
2
AWG26
Table 4: Push / pull
Q
Push-pull
(
≤
100 mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Q
Push-pull
(
≤
100 mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Alarm
Alarm output: The sensor (WEO16P, WEO16I) features a pre-failure notification output
(“Alarm” in connection diagram
, which issues a notification if the sensor is only
ready for operation to a limited extent. The LED indicator flashes in this case. Possible
causes: Sensor or reflector is contaminated, sensor is out of alignment. In the good
state: LOW (0), if excessively contaminated HIGH (1).
5
ELECTRICAL INSTALLATION
8
8020353 | SICK
Subject to change without notice
Summary of Contents for WSE16 Series
Page 1: ...O P E R A T I N G I N S T R U C T I O N S WSE16...
Page 2: ...O P E R A T I N G I N S T R U C T I O N S WSE16 de en es fr it ja pt ru zh...
Page 14: ...B E T R I E B S A N L E I T U N G WSE16 de en es fr it ja pt ru zh...
Page 26: ...N O T I C E D I N S T R U C T I O N WSE16 de en es fr it ja pt ru zh...
Page 38: ...M A N U A L D E I N S T R U E S WSE16 de en es fr it ja pt ru zh...
Page 50: ...I S T R U Z I O N I P E R L U S O WSE16 de en es fr it ja pt ru zh...
Page 62: ...I N S T R U C C I O N E S D E U S O WSE16 de en es fr it ja pt ru zh...
Page 74: ...WSE16 de en es fr it ja pt ru zh...
Page 85: ...WSE16 de en es fr it ja pt ru zh...
Page 97: ...WSE16 de en es fr it ja pt ru zh...
Page 108: ...C WS WE WS WE WE WS 63 60 88 89 SICK 88 108 8020353 SICK Subject to change without notice...