7
Operation
7.1
LED behavior during teach-in
The status LED supports the teach-in process,
see "Status indicators", page 12
7.2
Teaching in the digital output
7.2.1
Factory settings of the digital output
•
N/O contact
•
Switching point (DtO) at maximum operating range
7.2.2
Teaching in the switching point, IO-Link: Single point (DtO) or single point + 8% (DtO + 8%)
When the object is located below the taught-in switching point, the digital output is
active.
Teaching in the switching point (distance to object as switching point)
1
1.
Position the object at
1
.
2.
Apply L+ at Teach-in for 3 seconds until both LEDs are flashing simultaneously.
✓
Both LEDs flash alternately.
3.
Apply L+ at Teach-in for 1 second.
✓
The switching point is taught in. The device automatically switches to normal
operation mode.
Teaching in the switching point + 8% (di 8% as switching point)
1
1.
Position the object at
1
.
2.
Apply L+ at Teach-in for 3 seconds until both LEDs are flashing simultaneously.
✓
Both LEDs flash alternately.
3.
Apply L+ at Teach-in for 3 seconds until both LEDs are again flashing alternately.
✓
The switching point is taught in. The device automatically switches to normal
operation mode.
7.2.3
Teaching in the switching window, IO-Link: Window (window mode)
When the object is located within the taught-in switching window, the digital output is
active.
Teach in the switching window
OPERATION
7
8016973/1BNC/2022-02-23 | SICK
O P E R A T I N G I N S T R U C T I O N S | UM12
21