background image

11 Internal circuitry

Fig. 1:  Internal circuitry UE48-3OS

12 Application examples

Fig. 2:  Basic circuit UE48-3OS: voltage supply, dual-channel output circuit (see technical

specifications)

Fig. 3:  Example of single-channel emergency switching off with manual reset

Fig. 4:  Example of dual-channel emergency switching off with cross-circuit monitoring, manual reset,

external device monitoring

Fig. 5:  Example of dual-channel guard protection with cross-circuit monitoring and manual reset

Fig. 6:  Example of an electrosensitive protective device (ESPE) with active output signal switching

devices (OSSD), manual reset, external device monitoring

13 Technical specifications

13.1 Data sheet

Minimum

Typical

Maximum

General system data
Safety integrity level

1)

SIL3 (IEC 61

 

508)

SIL claim limit

1)

SILCL3 (EN 62

 

061)

Safe failure fraction (SFF)

90

 

% (EN 62

 

061)

Hardware fault tolerance (HFT)

1 (EN 62

 

061)

Category

Category 4 (EN ISO 13

 

849)

Performance Level

1)

PL e (EN ISO 13

 

849)

B

10D

 value (relay)

AC-15, 230 V, I = 1.5 A

I = 0.75 A

DC-13, 24 V,  I = 2.5 A

I = 0.63 A

1.26 × 10

6

 switching operations

5.9 × 10

6

 switching operations

435

 

 × 10

3

 switching operations

10 × 10

6

 switching operations

PFH

D

 (mean probability of a dangerous failure per

hour)

2)

3 × 10

–8

T

M

 (mission time)

20 years (EN ISO 13

 

849)

Stop category

0 (EN 60

 

204-1)

Supply voltage (A1, A2)
Input voltage (A1, A2)

AC operation

21.6 V

24 V

26.4 V

DC operation

20.4 V

24 V

26.4 V

Voltage supply (A1, A2)

Output current circuits >

 

25 V AC/60 V DC

PELV

Output current circuits

 

25 V AC/60 V DC

SELV or PELV

Residual ripple with DC operation

(within the limits of V

S

)

2.4 V

SS

Power consumption

AC operation

5 VA

DC operation

2.6 W

Nominal frequency for AC operation

50 Hz

60 Hz

1)

  The Performance Level actually attained depends on the application. For detailed information on the exact design of

your machine/system, please contact your local SICK representative.

2)

  With DC = 99

 

% and MTTF

D

 = 100 a (according to EN ISO 13

 

849, Tab. K1 and formula C.7) and 8760 switching

operations/a.

Removable terminal
Device connection
Removable terminal
Device connection

Removable terminal

Device connection

Removable terminal

Device connection

Reviews: