background image

2

Scope

These operating instructions are only applicable to the UE10-3OS basic device expan‐
sion modules with the following entry on the type label in the field Operating Instruc‐
tions: 8022170

You will find the device’s date of manufacture on the type label in the field Date Code in
the format yywwxxxx (yy = year, ww = calender week, xxxx = serial number).

These operating instructions are original operating instructions.

SCOPE

4

O P E R A T I N G   I N S T R U C T I O N S | UE10-3OS

8022191/2017-11-24 | SICK

Subject to change without notice

Summary of Contents for UE10-3OS

Page 1: ...O P E R A T I N G I N S T R U C T I O N S UE10 3OS Expansion module for basic devices SR UE10 ...

Page 2: ...protection 6 4 Product description 7 5 Mounting 8 6 Electrical installation 9 7 Commissioning and regular tests 10 8 In the event of faults or errors 11 9 Compliance with EU directives 12 10 Internal circuitry 13 11 Technical specifications 14 11 1 Data sheet 14 11 2 Dimensional drawings 16 CONTENTS 2 O P E R A T I N G I N S T R U C T I O N S UE10 3OS 8022191 2017 11 24 SICK Subject to change with...

Page 3: ...mber of signalling current N C con tacts Number of contactor monitoring N C contacts Type Part number Plug in spring termi nals 3 1 1 SR UE10 1092502 ORDERING INFORMATION 1 8022191 2017 11 24 SICK O P E R A T I N G I N S T R U C T I O N S UE10 3OS 3 Subject to change without notice ...

Page 4: ...rating Instruc tions 8022170 You will find the device s date of manufacture on the type label in the field Date Code in the format yywwxxxx yy year ww calender week xxxx serial number These operating instructions are original operating instructions 2 SCOPE 4 O P E R A T I N G I N S T R U C T I O N S UE10 3OS 8022191 2017 11 24 SICK Subject to change without notice ...

Page 5: ...mit achieved depends on the external cir cuit the design of the wiring the selection of the control switch and its placement on the machine The UE10 3OS expansion module has been evaluated to UL 508 The UE10 3OS expansion module is used for electro sensitive protective equipment ESPE with monitored active output signal switching device OSSD single channel dual channel in accordance with IEC 61 496...

Page 6: ... is used are responsible for obtaining and observing all applicable safety regulations and rules The tests must be carried out by qualified safety personnel or specially qualified and authorised personnel and must be recorded and documented to ensure that the tests can be reproduced and retraced at any time by third parties The operating instructions must be made available to the operator of the m...

Page 7: ... path is not a safe output The feedback current path is used as external device monitoring for the monitoring by the basic device DANGER In order to attain SIL3 PL e connect the external device monitoring In order to reach SIL3 PL e an external diagnosis with DC 99 must be applied i e the external device monitoring must be connected Table 1 Status indicators Display Meaning K1 O Green Channel 1 sw...

Page 8: ...o be mounted in the control cabinet The control cabinet must at least comply with enclosure rating IP 54 b Mounting in accordance with EN 50274 b Mounting on a 35 mm mounting rail EN 60715 5 MOUNTING 8 O P E R A T I N G I N S T R U C T I O N S UE10 3OS 8022191 2017 11 24 SICK Subject to change without notice ...

Page 9: ...cuits Please also note that the selection of the arc suppression can increase the total response time of the safety function The output signal switching devices and the external device monitoring EDM must be wired in the control cabinet To prevent the welding of the contacts on the built in relay an overcurrent protec tion device with max 6 A short circuit protection duty class gG is to be integra...

Page 10: ... area against entry Regular inspection of the protective devices by qualified safety personnel b Check the system following the inspection intervals specified in the national rules and regulations Each safety application must be checked at an interval specified by you The effectiveness of the protective devices must be checked daily by a spe cialist or by authorised personnel b If changes have bee...

Page 11: ...t clearly identify or allocate the error and if you can not safely rectify the malfunction DANGER Complete function test after rectification of fault b After rectifying a fault perform a complete function test IN THE EVENT OF FAULTS OR ERRORS 8 8022191 2017 11 24 SICK O P E R A T I N G I N S T R U C T I O N S UE10 3OS 11 Subject to change without notice ...

Page 12: ...h the provisions of the following EU directive s including all applicable amendments and that the respective standards and or technical specifica tions are taken as the basis Complete EU declaration of conformity for download www sick com 9 COMPLIANCE WITH EU DIRECTIVES 12 O P E R A T I N G I N S T R U C T I O N S UE10 3OS 8022191 2017 11 24 SICK Subject to change without notice ...

Page 13: ...l circuitry Figure 1 Internal circuitry UE103OS Figure 2 Basic circuit UE103OS INTERNAL CIRCUITRY 10 8022191 2017 11 24 SICK O P E R A T I N G I N S T R U C T I O N S UE10 3OS 13 Subject to change without notice ...

Page 14: ...ircuits 25 V AC 60 V DC SELV or PELV on B1 B2 B3 B4 Power consumption total power 2 1 2 W Switch on current 500 mA Power up delay B1 B2 B3 B4 40 ms Output current circuits 13 14 23 24 33 34 41 42 Y1 Y2 Reactivation delay K1 K2 response time of the protective function 16 ms 20 ms Contact material and surface finish Ag Sn O2 2 µm Au Enable current paths normally open contact safety relevant 3 Signal...

Page 15: ...tions Switching current A AC 15 230 V AC 1 230 V DC 1 24 V DC 13 24 V Contact clearance 1 2 mm tLB Arc duration L R 40 ms tLB 5 ms L R 40 ms tLB 5 ms L R 0 ms tLB 5 ms Operating data Protection against physical contact EN 60 6641 EN 60 9471 Rated impulse voltage VImp 4 kV Overvoltage category II4 Rated voltage 300 V AC Test voltage Urms 50 Hz 2 kV Enclosure rating Housing IP 40 EN 60 529 Terminals...

Page 16: ...ications Connection cross section AWG 26 14 only use 60 75 C copper flexible wire Tightening torque 5 7 lb in Weight 200 g 11 2 Dimensional drawings 107 6 78 58 93 3 96 5 93 7 22 5 75 3 114 5 1 14 8 5 1 14 8 109 89 8 71 3 Figure 3 Dimensional Drawing UE10 3OS with removable terminals 11 TECHNICAL SPECIFICATIONS 16 O P E R A T I N G I N S T R U C T I O N S UE10 3OS 8022191 2017 11 24 SICK Subject t...

Page 17: ...m Mexico Phone 52 472 748 9451 E Mail mario garcia sick com Netherlands Phone 31 30 2044 000 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree E Mail sales sick co nz Norway Phone 47 67 81 50 00 E Mail sick sick no Poland Phone 48 22 539 41 00 E Mail info sick pl Romania Phone 40 356 171 120 E Mail office sick ro Russia Phone 7 495 775 05 30 E Mail info sick ru Singapore Ph...

Reviews: