10
TECHNICAL DATA
42
SAFETY-RELATED 2D LIDAR SENSOR | TIM361S
8022483/108R/2018-07-09 | SICK
Subject to change without notice
Characteristic
Values
Protective field/Field
analysis
1 analysis case with 1 field set and up to
3 independent protective fields, signaling of field
infringements via a combination of 3 PNP switching
outputs (OUT1 … OUT3)
Protective field tolerance
+100 mm; 0.66° acc. To DIN CLC/TS 62046:2009 at
5% remission
Temperature drift: 1.5 mm/Kelvin
Number of field sets
16 field sets with 3 independently configurable
protective fields each
Switching inputs
PNP inputs: 4 x IN, IN1 … IN4,
(U
e
= max. 28 V, I
e
= max. 5 mA), opto-decoupled,
debounce approx. 10 ms
Switching outputs
PNP outputs: 4 x OUT, OUT1 … OUT4, (each I
a
max.
100 mA), not electrically isolated from supply voltage,
short-circuit protected/ temperature protected
Configurable for OUT 1 … OUT 3:
Response time (67 ms … 30 s)
Duration time (0 ms … 10 s)
For further technical specifications, see the online data sheet on the product page on
the web (
NOTE
The product is intended for use in industrial environments, under indoor conditions. It
is not suitable for use in special surroundings (e.g., radiation and sparks from welding
systems, strong sources of infrared, thermal convection, fluorescent and stroboscopic
light sources, snow, rain, contamination) or must yet be made suitable, if applicable.
2
The TiM has an internal, system-related time delay of 67 ms