background image

T i M 3 5 x / T i M 3 6 x   |   S i C K

8016903/ZP97/2017-07-27 • Subject to change without notice • 

SICK AG

 • 

Waldkirch

 • 

Germany

 • 

www.sick.com

5

Model name

TiM351-2134001 (Part no. 1067299)

TIM361-2134101 (Part no.  1071399)

Damp heat

According to EN 60068-2-30: 2005-12

Air humidity

< 80%

installation height

 < 5,000 m above sea level

Ambient condi-

tions

According to EN 61010-1:2011-07, contamina

-

tion level 3 outside housing

1) 

T < -15 °C: typ. 7.5 m at 10% Remission

2)  Complies with 21 CFR 1040.10 and 1014.11 except for the deviations pursu

-

ant to Laser Notice No. 50 of June 2007

3) 

The TiM has an internal, system-related delay time of 67 ms. 

For further technical specifications, see the 

Online data sheet

 

on the product website (

www.sick.com/tim3xx

).

 

a

WARNiNG

Risk of potential equalization currents 

The TiM is designed to be operated in a system with proper 
grounding of all connected devices and mounting surfaces 
to the same ground potential. If this condition is not met, 
potential equalization currents may through along the cable 

shields, causing the following hazards:

• 

Dangerous contact voltage on the metal housing

•  Malfunction or destruction of the TiM 
•  Heating of the cables with possible spontaneous combus-

tion. 

 

>

See the "

Electrical installation

“ chapter in the 

&

 

Technical 

Information

 (no. 8014318) on the product site on the web 

(

www.sick.com/tim3xx

) for measures to eliminate hazards.

 

a

ATTENTiON

Risques liés à des courants d’équipotentialité

Le TiM a été conçu pour être utilisé dans une installation 
prévoyant une mise à la terre correcte de tous les appareils 
et surfaces de montage raccordés sur un même potentiel de 
sol. Si cette condition n’est pas remplie, des courants d’équi

-

potentialité risquent dans certaines conditions de passer par 
les blindages des câbles et d’exposer aux risques suivants :

• 

tension de contact dangereuse sur le boitier en métal,

•  comportement incorrect ou destruction du TiM.
• 

chauffe des câbles jusqu’à leur inflammation spontanée. 

 

>

Pour des mesures de prévention de tels risques, voir le 
chapitre « Installation électrique » de 

&

 

l’Information tech-

nique

 (no. 8014318) ou sur la page produit sur internet 

(

www.mysick.com/en/tim3xx

).

Pin assignment for rotary corners
Connection plug pin positions

“Power/switching inputs/outputs” connection

12-pin M12 plug on the cable

IN 4 (switching input)

IN 3 (switching input)

IN 1 (switching input)

IN 2 (switching input)

DC 9 ... 28 V

GND

n.c.

OUT 1 (switching output)

OUT 2 (switching output)

7

6

OUT 4 (switching output)

OUT 3 (switching output)

4

3

2

1

5

8

9

10

11

12

4

10

11

12

8

6

7

9

1

5

3

2

PNP: INGND

NPN: IN 9 ... 28 V

 

(Reference potential for 

                                           switching inputs)

Ethernet connection (6034415)

4

3

2

1

TD+

TD–

RD+

RD–

4

3

2

1

“Ethernet” connection 

M12 socket, 

D-encoded

Maintenance and care

The TiM does not contain any components that require main-
tenance. Maintenance is not necessary to ensure compliance 
with laser class 1.

 

>

If it is dirty, carefully clean the infrared light-permeable, 
black optical hood to ensure optimal detection perfor-

mance. Use a soft, damp cloth and a mild cleaning agent.

Transport and storage

The TiM must be transported and stored in its original pa-

ckaging with the USB protective cap plugged in. Do not store 

outdoors. To ensure that any residual moisture present can 

escape. Do not expose to aggressive media (e. g., solvents).

Storage conditions: dry, dust-free, no direct sunlight, as little 
vibration as possible, storage temperature –40°C to +75°C, 
relative air humidity max. 90% (non-condensing).

Repair

Repair work on TiM35x may only be performed by qualified 

and authorized service personnel from SICK AG.

Removal and disposal

Any TiM35x which can no longer be used at the end of the 
product life cycle must be disposed of in an environmentally 
friendly manner in accordance with the respective applicable 

country-specific waste disposal regulations.

The TiM35x is electronic waste and must under no circum-

stances be disposed of with general waste!

Sources for obtaining additional informat

Additional information about the TiM and its optional acces-

sories can be found in the following places:

Product web page for the TiM3xx

 

(www.sick.com/tim3xx)

•  Technical Information (supplementary information on 

mounting and electrical installation, an overview list, and 
license texts for open-source software) in German (no. 

8014317) and English (no. 8014318).

• 

These operating instructions in German (no. 8016902), 
English (no. 8016903), and in other languages if required

• 

SOPAS configuration software with online help

•  Ordering information in the detection and ranging solu-

tions product catalog

•  TiM3xx product information
• 

Detailed technical specifications (online data sheet)

• 

Dimensional drawing and 3D CAD dimension models in 

various electronic formats

• 

EC declaration of conformity

• 

SOPAS configuration software updates 

Support is also available from your sales partner: 

www.sick.

com/worldwide.

Copyright notices for open-source programs

SICK uses open source software in its TiM sensors. This 
software is licensed by the rights holders using the following 

licenses among others: the free licenses GNU General Public 
License (GPL Version2, GPL Version3) and GNU Lesser Gen

-

eral Public License (LGPL), the MIT license, zLib license, and 
the licenses derived from the BSD license. 

This Program is distributed in the hope that it will be useful, 

but WITHOUT ANY WARRANTY; without even the implied war

-

ranty for merchantability or fitness for a particular purpose. 

See the GNU General Public License for more details. 

View the complete license texts here: 

www.sick.com/licen-

setexts

.

A printed copy of the license texts is also available on request.

 

Reviews: