Sensing ranges for “Mini” actuator
Table 28: Sensing ranges for “Mini” actuator
Alignment of sensor and actuator
Assured switch-
on distance S
ao
Assured switch
off distance S
ar
Minimum dis‐
tance with paral‐
lel approach
≤
10 mm
≤
14 mm
1)
≥
28 mm
10 mm
≤
10 mm
≤
14 mm
1)
≥
28 mm
10 mm
≤
4 mm
≤
9 mm
1)
≥
20 mm
4 mm
≤
4 mm
≤
9 mm
1)
≥
20 mm
4 mm
1)
Only applies in limited temperature range of –10 °C … +70 °C. Devices with serial number 1824*** or
lower only support the limited temperature range. The serial number is displayed on the safety switch
over the data matrix code.
Sensing ranges for “Compact” actuator
Table 29: Sensing ranges for “Compact” actuator
Alignment of sensor and actuator
Assured switch-
on distance S
ao
Assured switch
off distance S
ar
Minimum dis‐
tance with paral‐
lel approach
≤
10 mm
≥
25 mm
5 mm
11
TECHNICAL DATA
42