PIN
Function
5
D4+
6
D4-
7
D3-
8
D3+
Additional notes
The Ethernet connections can be used to connect to cameras and SICK LiDAR scanners
as well as a PC or network.
The relevant drivers for using SICK LiDAR scanners and the picoCam and midiCam
camera families as well as GigE Vision compatible cameras have been implemented in
the SIM.
Jumbo frame support is required when using Ethernet switches.
Transmission rates
:
ETH1 - 4: 0.01; 0.1; 1, 2.5 Gb/s
ETH1-4: with PoE Out
•
PoE voltage supply is factory deactivated
PoE according to class 4
6.7
Connecting peripheral devices
The device can be connected to a wide range of sensors and cameras. The required pin
assignments can be found in the data sheets for the peripherals to be connected as
well as in the relevant connection descriptions,
see "Pin allocation of the connections",
.
1.
If necessary, assemble connection cables,
see "Preparing the cables", page 19
.
2.
Connect the cables to peripheral devices.
3.
Route the cables to the device using installation materials (cable channels, cable
ties, etc.). When doing so, pay attention to cable strain relief.
4.
Connect cables to the relevant device connections.
5.
Seal unused connections with dummy plugs.
6.
Ensure that the power output to the sensor via the device does not exceed 140 W.
6.8
Connecting voltage supply
NOTICE
Risk of damage to peripheral devices!
If peripheral devices are connected when the voltage supply is also applied, these
devices can become damaged.
■
Only connect peripheral devices when the voltage supply is disconnected.
1.
Ensure that the voltage has been disconnected by the user.
2.
Connect the voltage supply cable(s) to the device.
3.
Lay the cable(s) with strain relief.
4.
Have the user connect the voltage supply.
5.
Have the user activate the voltage.
6
ELECTRICAL INSTALLATION
28
O P E R A T I N G I N S T R U C T I O N S | SIM2500
8023295 //2021-06-22 | SICK
Subject to change without notice