Suitable cable lugs
•
Forked cable lug or ring cable lug
•
Width ≤ 10 mm
•
Hole diameter for screw: typically 4.1 mm
The functional earth must be connected in a low-inductance manner and with an
adequate cross-section while keeping the cable length as short as possible.
6.6
Pin allocation of the connections
6.6.1
POWER IN
1
4
3
2
Figure 2: POWER IN pin assignment, M12 - 4-pin T-coded, male
Table 2: POWER IN
PIN
Signal
Color coding on the
SIM power cable e.g.,
6059939*
Function
1
+ 24 V IN1
BN (brown)
IN1 supply voltage
2
GND IN2
WH (white)
Ground
3
GND IN1
BU (blue)
Ground
4
+ 24 V IN2
BK (black)
IN2 supply voltage (redundant)
Housing
-
-
Screen
*
SICK cables in the SIM accessories
Additional notes
•
Max. 7.5 A permanent load
•
Supply voltage “IN1” and “IN2” can be set up redundantly.
Observe the requirements for the design of overcurrent protective devices according to
EN 61010.