background image

O P E R A T I N G   I N S T R U C T I O N S

SIM1012

Sensor Integration Machine

Summary of Contents for SIM1012

Page 1: ...O P E R A T I N G I N S T R U C T I O N S SIM1012 Sensor Integration Machine...

Page 2: ...ble within the limits of the legal determination of Copyright Law Any modi fication abridgment or translation of this document is prohibited without the express written permission of SICK AG The trade...

Page 3: ...ace 12 3 4 Preset Ethernet interfaces 12 4 Transport and storage 13 4 1 Transport 13 4 2 Transport inspection 13 4 3 Storage 13 5 Mounting 14 5 1 Overview of mounting procedure 14 5 2 Scope of deliver...

Page 4: ...7 10 1 Disposal 27 11 Technical data 28 11 1 Features 28 11 2 Interfaces 28 11 3 Mechanics and electronics 29 11 4 Ambient data 30 12 Annex 31 12 1 Dimensional drawings 31 12 2 Licenses 31 CONTENTS 4...

Page 5: ...n on operating the machine or system in which the device is integrated Information on this can be found in the operating instructions for the machine or system 1 2 Explanation of symbols Warnings and...

Page 6: ...Dimensional drawings and 3D CAD dimension models of the device types in various electronic formats Other publications related to the devices described here Publications dealing with accessories 1 4 S...

Page 7: ...s are possible depending on the device specific properties The device is programmed on a PC by using the development environment software SICK AppSpace Depending on the application a browser based gra...

Page 8: ...nufacturer accepts no liability for damage caused by Non adherence to the product documentation e g operating instructions Incorrect use Use of untrained staff Unauthorized conversions or repair Techn...

Page 9: ...e work safety regulation The following qualifications are required for various activities Table 1 Activities and technical requirements Activities Qualification Mounting maintenance Basic practical te...

Page 10: ...tial equalization currents Improper grounding can lead to dangerous equipotential bonding currents which may in turn lead to dangerous voltages on metallic surfaces such as the housing Electrical volt...

Page 11: ...d connection 3 2 Functionality The SIM1012 Sensor Integration Machine part of the SICK AppSpace ecosystem is opening up new possibilities for application solutions Data from SICK sensors such as laser...

Page 12: ...g the device can be found at supportportal sick com 3 4 Preset Ethernet interfaces NOTE Preset IP addresses of the ETHERNET interfaces ETHERNET 1 192 168 0 1 ETHERNET 2 192 168 1 1 When expanding the...

Page 13: ...transit In the case of transit damage that is visible externally proceed as follows Do not accept the delivery or only do so conditionally Note the scope of damage on the transport documents or on th...

Page 14: ...have been ordered or owing to the latest technical changes the actual scope of delivery may vary from the features and illustra tions shown here 5 3 Preparing for mounting Installation requirements Se...

Page 15: ...t be con nected NOTE Layout of data cables Use screened data cables with twisted pair wires Implement the screening design correctly and completely To avoid interference e g from switching power suppl...

Page 16: ...k receiver transceiver 3 ETHERNET 2 x 1 Gigabit Ethernet 4 SENSOR S1 S6 Connections with digital inputs outputs and voltage supply Can be alternatively used as IO Link master connections 5 INC 1 x inc...

Page 17: ...ection while keeping the cable length as short as possible 6 5 Pin allocation of the connections 6 5 1 POWER 1 4 3 2 Table 2 POWER pin assignment M12 4 pin T coded male Pin Signal Function 1 24 V IN1...

Page 18: ...485 2 MBaud TTL encoders use RS 422 and can be connected via the SERIAL interface 6 5 3 INC Incremental connections for encoders can also be used as serial connections for RS 422 1 7 2 6 3 4 5 8 Table...

Page 19: ...3 2 A output for supply voltage connections compliant with LPS To enable voltage supply to the peripherals both voltage supply strands of the POWER connection must be connected to 24 V 6 5 5 SENSOR 1...

Page 20: ...re be connected via the digital inputs Recommendation when using S1 to S6 for illumination Short flash times can be achieved by using an illumination unit with signal strobe and by using pin4 as a dig...

Page 21: ...evices 2 Route the cables to the device using installation materials cable channels cable ties etc When doing so pay attention to cable strain relief 3 Connect cables to the relevant device connection...

Page 22: ...environment for the time being to check network communication if necessary Note the company standards that apply to the use of checking and testing devices For initial programming use ideal conditions...

Page 23: ...plant area into which the device is incorporated Meaning of symbols Symbol Purpose LED off LED on LED flashes LED goes out briefly LED lights up briefly LED flashes bicolored Device status Location De...

Page 24: ...or short circuit detected No signal activity Overcurrent or short circuit detected Signal activity SERIAL Location Designation LED behavior Description PWR ACT Voltage not applied to the connection V...

Page 25: ...ermination resistor acti vated SENSOR S1 S6 Location Designation LED behavior Description PWR ACT Voltage not applied to the connection Voltage applied No signal activity Voltage applied Signal activi...

Page 26: ...ntenance tasks may be required for the device at regular intervals Table 8 Maintenance plan Maintenance work Interval To be carried out by Check device and connecting cables for damage at regular inte...

Page 27: ...y manner in accordance with the applicable country specific waste disposal regulations Do not dispose of the product along with household waste NOTICE Danger to the environment due to improper disposa...

Page 28: ...256 MB in total 30 MB of which available for applications Memory card optional Industry grade microSD memory card flash card max 32 GB Programming software SICK AppStudio Sensor data processing Accord...

Page 29: ...oded SERIAL 1 x M12 8 pin female connector A coded CAN 1 x M12 5 pin female connector A coded SENSOR S1 S6 IO Link master 6 x M12 5 pin female connector A coded ETHERNET 2 x M12 8 pin female connector...

Page 30: ...00 02 A2 2013 10 requires blind plugs to be inserted into unused con nections Ambient conditions Operation site Height position Degree of contamination Use inside buildings max 2 000 m 1 Ambient opera...

Page 31: ...en source software which is published by the rights holders under a free license Among others the following license types are used GNU General Public License GPL version 2 GPL version 3 GNU Lesser Gen...

Page 32: ...080 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mexico sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree E...