background image

1 Safety

b

 Read these operating instructions before using the device.

b

 Connection, assembly, and settings must be performed by 

competent technicians.

b

 Do not connect external I/O signals to the device while it is 

powered. This may damage the device.

b

 Protect the device from moisture and dirt during operation.

b

 Do not use the device in areas with risk for explosion.

b

 Safe operation of lasers (accessory) depend on the type of 

lasers being used. Carefully read the safety instructions in 

the laser’s manual.

2 Product Specification

Ranger C is a high-speed 3D camera that can measure up to 

30,000 shape profiles/s. The camera can also operate in a 

MultiScan mode, where it can simultaneously measure 3D, 

grayscale, scatter, gloss, etc. 
The Ranger serves as a data streamer, from which the 

measurement data is transferred through a CameraLink 

connection to a PC for further processing.

The Ranger C can be started, stopped and configured by 

applications running on the PC. Note that the Ranger C 

Development software is required to build such applications.
The Ranger C is intended to be the vision component in a 

machine vision system.

The ISM Radio Frequency Classification is Group 1, Class A 

(EN55011). 

Warning:

  Class A equipment is intended to be used in an 

industrial environment. 

3 Connections 

 B 

Ranger C is connected to a 12 … 24 V DC power supply, and 

to a PC running Windows 7/XP equipped with a CameraLink 

frame grabber board:

b

 The power supply is connected to the Power I/O connector 

(14-pin female LEMO connector).

b

 The frame grabber board in the PC is connected to the 

CameraLink connector (26 position MDR female plug)

b

 I/O signals that are used, for example pulse trigger signals 

from encoders or the laser trigger signal from the Ranger C 

camera, are also connected to the Power I/O connector.

4 System Requirements

b

 PC 

Recommended: Windows 7/XP Professional, 

3 GHz processor, 1024 MB memory, 

 

800 MHz bus speed.

 

 

For evaluation, a PC with lower specifications 

may be sufficient.

b

 Cables

 

- CameraLink  Up to 10 m when using a CameraLink pixel 

clock rate of 33 MHz. 

 

Up to 3 m for a pixel clock rate of 66 MHz.

 

- Power I/0 

Up to 50 m.

5 Installation 

 C 

b

 Install the frame grabber board (

 a 

) and the Ranger C 

Development software (

 b 

) on the PC.

b

 Attach a lens to the Ranger C (

 c 

).

b

 Mount the Ranger C, additional light sources, and other 

equipment to be used by the vision system such as encod-

ers and photoelectric switches for triggering.

b

 If the I/O signals are used, connect the equipment using the 

signals to the Power I/O connector of the Ranger C.

 

A Ranger M/C Power-I/O terminal (

 d 

) can also be used 

for connecting I/O signals to the Ranger C. It offers screw 

terminals for connecting the signals, and connects to the 

Ranger C with a SAH Power & I/O cable (

 e 

).

b

 Connect the CameraLink connector on the Ranger C to a 

CameraLink connector on the frame grabber board installed 

in the PC, using a CameraLink cable (

 f 

). The PC should be 

unpowered.

b

 Connect an unpowered 12 … 24 V DC power supply (

 g 

) to 

the Power I/O connector on the Ranger C, or to the power 

plug on the Ranger M/C Power-I/O terminal.

b

 Switch on the power supply.

6 Service and Maintenance

The Ranger C contain no user serviceable parts inside. The 

warranty of the device will be void if opened.

b

 Check screw connections and connectors at regular 

intervals.

b

 Clean the housing with a soft cloth, dry or dampened with a 

mild water diluted cleaning agent without powder additives.

In case of unit failure, please contact SICK or a SICK represen-

tative that delivered the unit for further instructions.

7 Further Information

For more information on the Ranger C, please refer to the 

Ranger C Operating Instructions and Reference Manual.
For support issues, please contact technical support on email: 

[email protected]
More product information is also available on  

www.sick.com.

 A 

 B 

Ranger C

C40

C50

C50-IR

C55

C55-IR

Imager

CMOS

Pixel resolution (columns x rows)

512 x 512

1536 x 512

1536 x 512

1536 x 512

1536 x 512

High resolution row (columns)

3072

3072

Optics (C-mount)

1/2-inch

1-inch

1-inch

1-inch

1-inch

IR filter 

(1)

IR high pass

IR high pass

Interfaces

CameraLink

Inputs

5 x TTL level

Outputs

1 x TTL level

Weight (without optics)

390 g

Dimensions (L x W x H)

109 x 50 x 50

Supply voltage

12 … 24 V DC

Power consumption

8 W, 1.25 A

Connectors: Power & I/O

 

CameraLink

LEMO, 14-pin, female  

Mini D Ribbon (MDR), 26 contacts, female

Camera house temperature

+5 … +50 °C

Enclosure rating

IP  20

Housing material

Aluminum

Type code

Ranger-C40412 Ranger-C50412 Ranger-C50422 Ranger-C55412 Ranger-C55422

Part number

1014218

1014216

1014223

1014217

1014224

(1) Half transmission at 750 nm. Row 100-511 with filter. Row 0-10 without filter.

Accessories

Part.No.

Ranger C Accessory kit

1014313

CameraLink frame grabber, X64 CL single board  (

 a 

)

6030530

3D Camera Development software  (

 b 

)

2047925

Lens, 25 mm, F1.4  (

 c 

1014252 

(3)

Ranger M/C Power-I/O terminal  (

 d 

1014284 

(3)

Power & I/O cable, 3 m  (

 e 

)  

(2)

1014266 

(3)

CameraLink cable, 3 m  (

 f 

)  

(2)

1014310 

(3)

Ranger Power supply, 24 V DC, with line cords  (

 g 

)

2040591 

(3)

Terminal box, ICT-B  (

 h 

1028342  

Laser triangulation parts  (

 i 

)

1014254

Laser, 660 nm, 35 mW  (

 k 

)

6033005

Camera mounting parts  (

 m 

)

1014255 

(3)

(2) Cables are available in different lengths. 

(3) Included in the Ranger C Accessory kit

PoWeR I/o
ConneCtoR

Pin

Signal

Remark

1

Reserved

Reserved 

2

Reserved

Reserved 

3

In2

Mark counter up (TTL)  

4

In1

Mark counter down (TTL)

5

In0

Measurement enable (TTL) 

6

In4

Trig counter up (TTL) 

7

In3

Trig counter down (TTL)

8

Out0

TTL output 0 

9

Reserved

Reserved 

10

Reserved

Reserved 

11

nReset

Camera reset, active low 

12

Reserved

Reserved 

13

Gnd

Ground for Pwr, nReset, In0…4, Out0 

14

Pwr

Camera power supply, 12 … 24 V

 C 

1

2

3

4

5

6

7

13

14

11

12

10

9

8

CaMeRaLInk
ConneCtoR

Pin

Signal

Remark

1

Inner shield

Connects to signal ground. 

2

X0-

Data channel 0, - 

3

X1-

Data channel 1, - 

4

X2-

Data channel 2, - 

5

Xclk-

Pixel clock, - 

6

X3-

Data channel 3, - 

7

SerTC-

Serial data to camera, - 

8

SerTFG-

Serial data from camera, - 

9

CC1-

Camera control input 1, - 

10

CC2-

Camera control input 2, - 

11

CC3-

Camera control input 3, - 

12

CC4-

Camera control input 4, - 

13

Inner shield

Connects to signal ground. 

14

Inner shield

Connects to signal ground. 

15

X0+

Data channel 0, + 

16

X1+

Data channel 1, + 

17

X2+

Data channel 2, + 

18

Xclk+

Pixel clock, + 

19

X3+

Data channel 3, + 

20

SerTC+

Serial data to camera, + 

21

Serial data from camera, + 

22

CC1+

Camera control input 1, + 

23

CC2+

Camera control input 2, + 

24

CC3+

Camera control input 3, + 

25

CC4+

Camera control input 4, + 

26

Inner shield

Connects to signal ground. 

1

13

14

26

 E 

Profile

Back

 1 

 Mounting holes M3, 6 mm

 2 

 Mounting holes M3, 3.5 mm 

 3 

 CameraLink connector (MDR-26 female plug)

 4 

 Power I/O connector (14-pin LEMO female)

 5 

 LEDs:  COM  CameraLink connected and channel 

initialized (red)

 

PWR  Supply voltage OK (red)

 

USR1/  Camera is ready for measuring 

 

USR2  (yellow flashing)

Front

 4 

 

 3 

 

 2 

 

 1 

 

108.9

18.5

75
50

15.5

12.5

25

3

28

11

6

50

25

25

50

25

12.5

25

24.5

15.5

PC with  

CameraLink 

frame grabber

 k 

Ranger C

 f 

 d 

 e 

24 V DC

I/O signals

 

 c 

Laser power

5.3 V

 i 

24 V DC

90 … 260 V AC

 g 

Encoder

Photoelectric switch

 h 

 a 

 b 

Signal levels

Low

High

TTL input (Power I/O)

-0.5 … +0.8 V

+2.0 … +5.75 V

TTL output (Power I/O)

0 … +0.4 V

+2.4 … +3.3 V

Camera reset

-0.3 … +0.8 V

+2.4 … +3.6 V

 5 

 

 m 

8011742/UR84

 

∙ All rights reserved ∙

 Subject to change without notice

SICK AG  |  Waldkirch  |  Germany  |  www.sick.com

80xxxxx/XXxx/yyyy

-mm-dd 

∙ XX/XX 

∙ Pr

int

ed 

in 

Ger

man

(yyyy

-mm) 

∙ Subject 

to 

chang

wit

hout 

no

tice 

∙ The 

specif

ied 

pr

oduct 

featur

es 

and 

tec

hnical 

dat

do 

no

t r

epr

esent 

an

guar

ant

ee 

∙ A4 

sw 

int34

Australia

Phone +61 3 9497 4100

 

1800 33 48 02 – tollfree

E-Mail  [email protected]

Belgium/Luxembourg

Phone  +32 (0)2 466 55 66

E-Mail  [email protected]

Brasil

Phone +55 11 3215-4900

E-Mail  [email protected]

Ceská Republika

Phone +420 2 57 91 18 50

E-Mail  [email protected]

China

Phone +852-2763 6966

E-Mail  [email protected]

Danmark

Phone +45 45 82 64 00

E-Mail  [email protected]

Deutschland

Phone +49 211 5301-301

E-Mail  [email protected]

España

Phone +34 93 480 31 00

E-Mail  [email protected]

France

Phone +33 1 64 62 35 00

E-Mail  [email protected]

Great Britain

Phone +44 (0)1727 831121

E-Mail  [email protected]

India

Phone +91–22–4033 8333

E-Mail [email protected]

Israel

Phone +972-4-999-0590

E-Mail  [email protected]

Italia

Phone +39 02 27 43 41

E-Mail  [email protected]

Japan

Phone +81 (0)3 3358 1341

E-Mail [email protected]

Nederlands

Phone +31 (0)30 229 25 44

E-Mail  [email protected]

Norge 

Phone +47 67 81 50 00

E-Mail  [email protected]

Österreich

Phone +43 (0)22 36 62 28 8-0

E-Mail  [email protected]

Polska

Phone +48 22 837 40 50

E-Mail  [email protected]

Republic of Korea

Phone +82-2 786 6321/4

E-Mail  [email protected]

Republika Slovenija

Phone +386 (0)1-47 69 990

E-Mail  [email protected]

România

Phone +40 356 171 120 

E-Mail  [email protected]

Russia

Phone +7 495 775 05 34

E-Mail  [email protected]

Schweiz

Phone +41 41 619 29 39

E-Mail  [email protected]

Singapore

Phone +65 6744 3732

E-Mail  [email protected]

Suomi

Phone +358-9-25 15 800

E-Mail  [email protected]

Sverige

Phone +46 10 110 10 00

E-Mail  [email protected]

Taiwan

Phone +886 2 2375-6288

E-Mail  [email protected]

Türkiye

Phone +90 216 587 74 00

E-Mail  [email protected]

United Arab Emirates

Phone +971 4 8865 878

E-Mail  [email protected]

USA/Canada/México

Phone +1(952) 941-6780

 

1 800-325-7425 – tollfree

E-Mail  [email protected]

More representatives and agencies 

in all major industrial nations at 

www.sick.com

3D Camera

Q U I C K S tA R t

Ranger C

 

EN

7

6

5

4

3

2

1

0

0

100

200

300

400

500

8
7
6
5
4
3
2
1
0

0

100

200

300

400

500

0

100

200

300

400

500

35

30

25

20

15

10

5

0

 D 

Max. speed ½ pixel resolution

kHz

3D measurement speed

Sensor rows

Best resolution 

1

/

16

 pixel resolution

kHz

Hi3D speed

Sensor rows

MultiScan measurement speed

kHz

4 MultiScan components 

(3D, Hi-res gray, Gray, Scatter)

3D Sensor rows

Important for installation

b

 Ensure that both peripherals and the Ranger C are 

unpowered before connecting them 

b

 Ensure that connected peripherals or I/O signals are 

never powered when the Ranger C is unpowered. 

b

 Camera housing must be connected to chassis ground 

and the complete system should be installed as an 

electrically shielded installation.

To prevent ground loops:

b

 Connect the camera DC ground (Pin 13) to the 0 V on the 

DC power supply, never to chassis ground.

b

 Always use an isolated DC power supply.