Intended use
The WTT12L-Axxxx is an opto-electronic photoelectric proximity sensor withanalog dis‐
tance value output (referred to as “sensor” in the following) forthe optical, non-contact
detection of objects. If the product is used for anyother purpose or modified in any way,
any warranty claim against SICK AGshall become void.
4
Commissioning
4.1
Check the application conditions:
Analog output:
Refer to Table
and Diagram H3, H4 for the accuracy specifications of the
analog output.
Switching output:
Adjust the sensing range and distance to the object or background and the remission
capability of the object according to the corresponding diagram [H1, H2] (x = sensing
range, y = minimum distance between the object and background in mm (object
remission / background remission)). Remission: 6% = black, 90% = white (referring to
standard white as per DIN 5033).
The minimum distance (= y) for background suppression can be read from diagram
[H1
1
] as follows:
Example: x = 1,000 mm, y = 25 mm. That is, the background is suppressed at a
distance of > 25 mm from the sensor.
0
5
(0.2)
10
(0.39)
15
(0.59)
20
(0.79)
25
(0.98)
30
(1.18)
35
(1.38)
40
(1.57)
0
1
6%/90%
2
6%/90%
90%/90%
5
4
90%/90%
3
6%/90%
6
90%/90%
Min. distance from object to background in mm (inch)
1,000
(39.37)
2,000
(78.74)
3,000
(118.11)
4,000
(157.48)
Distance in mm (inch)
1) -Bxx3x: 6 % / 90 %
2) -Bxx3x: 90 % / 90 %
3) -Bxx6x: 6 % / 90 %
4) -Bxx6x: 90 % / 90 %
5) -Bxx4x: 6 % / 90 %
6) -Bxx4x: 90 % / 90 %
Figure: H
0
4
5
6
90%/90%
90%/90%
90%/90%
1
6%/90%
2
3
6%/90%
6%/90%
30
(1.18)
20
(0.79)
10
(0.39)
50
(1.97)
40
(1.57)
500
(19.69)
1,000
(39.37)
1,500
(59.06)
2,000
(78.74)
Min. distance from object to background in mm (inch)
Distance in mm (inch)
1) -Bxx1x: 6 % / 90 %
2) -Bxx1x: 90 % / 90 %
3) -Bxx5x: 6 % / 90 %
4) -Bxx5x: 90 % / 90 %
5) -Bxx2x: 6 % / 90 %
6) -Bxx2x: 90 % / 90 %
Figure: H-2
OPERATING INSTRUCTIONS
8020879.1D62/2022-08-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | PowerProx Analog – WTT12L-Axxx
21
Subject to change without notice
en
Summary of Contents for PowerProx WTT12L-A Series
Page 68: ...PowerProx Analog WTT12L Axxx MultiTask de en es fr it ja ko pl pt ru zh...
Page 80: ...PowerProx WTT12L Axxx de en es fr it ja ko pl pt ru zh...
Page 120: ...PowerProx Analog WTT12L Axxx de en es fr it ja ko pl pt ru zh...
Page 133: ...PowerProx Analog WTT12L Axxx de en es fr it ja ko pl pt ru zh...