Operating Instructions
Chapter
5
CLX490
8009237/RB47/2007-08-03
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-3
Electrical installation
5.2.3
Connections/cables for the AMV/S Connection Module
The AMV/S Connection Module is suitable for connecting the CLX to peripherals (distribution
function) and the power supply. The module can be used to establish a connection to the
host (point-to-point) or integrate the device in a SICK network or daisy-chain configuration
(pass-through or master/slave configuration). The module is available in several variants
(see
).
shows the connection principle of the AMV/S60 for one CLX.
Connecting the CLX to the AMV/S
Two cables no. 2020302 are required to connect the CLX to the AMV/S. Alternatively, the
device can be connected via the external parameter memory no. 2020307.
See
Chapter 5.2.5 Connections/cables for the external parameter memory (connection to
AMV/S or BMV10/BMS20), Page 5-4
a) CLX without heater:
Connection modules: AMV/S60 and AMV30-071.
The cables no. 2020302 can be extended to 10 m (auxiliary interface: RS 232!).
b) CLX with heater:
Connection modules: AMV100 and AMV200.
The cables no. 2020302 must
not
be extended!
If longer cables are required, the entire power supply system (Pin 1/Pin 5) must be
connected with a wire cross-section of at least 0.75 mm
2
with a maximum length of 10 m.
Recommendation
Use the cable no. 2021298 (with two connector covers, length 3 m).
The procedures for connecting and configuring the AMV/S Connection Modules are
described in the following documentation:
•
Operating Instructions for the "
AMV/S60 Connection Module"
(no. 8008296)
•
Operating Instructions for the "
AMV30-071 Connection Module"
(no. 8008648)
•
Operating Instructions for the "
AMV100/200 Connection Module"
(no. 8008879)
Fig. 5-1:
Block diagram: Connection of the CLX to the AMV/S60 connection module
Scanner
Decoder
Interface
"Terminal"
"Terminal"
"Host"
"Host"
"Result 1 ... 4"
"Result 1 ... 4"
"Sensor"
"In 0 ... 4"
DC 18 ... 30 V
"Sensor"
"In 0 ... 4"
Photoelectric
switch
Reading pulse
Photoelectric
switch
Focal position
Conveyor increment
Reading pulse end
CLX490
AMV/AMS60
connection module
HOST/PLC
PLC
18 to 30 V DC (AMV60-011)
230 V AC 50 Hz (AMS60-013)
115 V AC 50/60 Hz (AMS60-012)
– – Cable if required
PC