Electrical installation
MSC800-2300
Fig. 19: Terminals on the MSC800-2300 for mains voltage IN and supply voltage OUT
Connections for mains voltage IN on the MSC800-2300
Terminal
Color
Signal Function
-X100/1.
1
Gray
L
Mains voltage AC 100 ... 264 V / 50 ... 60 Hz (phase)
-X100/1.
4
Blue
N
Mains voltage AC 100 ... 264 V / 50 ... 60 Hz (neutral
conductor)
-X100/1.
5
Blue
N
-X100/1.
6
Green-yellow PE
Protective conductor
-X100/1.
7
Green-yellow PE
Tab. 15: MSC800-2300: -X100 terminal block pin assignment for mains voltage IN
Connections for supply voltage OUT 2 on the MSC800-2300 for ICR890
Terminal
Signal
Function
Protected by the
automatic circuit
breakers
-X120/
11
DC +24 V Supply voltage OUT 2 (power supply unit
module 2)
–F111
-X120/
13
DC +24 V
–F113
-X120/
15
DC +24 V
–F115
-X120/
12
GND
Ground (power supply unit module 2)
–
-X120/
14
GND
-X120/
16
GND
-X120/
17
Shield
Shield
-
-X120/
18
Shield
-X120/
19
Shield
Tab. 16 MSC800-2300: assignment of the -X120 terminal block for