3
Product description
3.1
Scope of delivery
The delivery of the device includes the following components:
Table 2: Scope of delivery
Item
Component
Comments
1
Device in the version ordered
Depending on version
Without connecting cables and brackets
1
Set of protective caps for electri‐
cal connections
Attached to the connections
1
Printed Safety Note, multilingual
(No. 8018793)
-
3.2
Status indicators
1
Figure 1: Status indicators
1
Status LEDs
Table 3: Display behavior of the LED
Orange LED
Green LED
Red LED
Yellow LED Status
O
Initialization
O
Ö
Configuration
Ö
O
Note (service recommended)
O
Ö
Warning (service required)
O
O
Risk (malfunction)
O
O
On / Ready for operation
O
Data transmission
O
= illuminated;
Ö
= flashing
3.3
Type code
The devices of the MRS6000 product family are arranged according to the following
type code:
PRODUCT DESCRIPTION
3
8022069/114M/2019-07-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | MRS6000
11