34
© SICK AG · Germany · All rights reserved · Subject to change without notice
8011984/YSZ3/2016-02-04
Chapter
5
Monitor
Online help
LMS400 laser measurement sensor
5.2.2
Display of the Level Control results
The measuring area (in white) and the columns configured (dotted lines) are shown on the
diagram. Columns with measured values are displayed colour-coded:
green = switching point not reached
red = switching point exceeded
Fig. 8:
Display of the Level Control results
You can change the size of the diagram using the buttons above the diagram.
Display
You can switch between “pure” scan data from the LMS400 and the column results from
the Level Control application.
Level Control
The column results are being displayed.
Scan
The measured data are displayed as red dots.
Coordinates
If you move the mouse pointer over the diagram, the pointer changes to cross wires. You
can see the values for the coordinates on the right beside the diagram.
The Y: and Z: read-only fields indicate the Y and Z coordinates of the mouse on the
diagram.
The D: read-only field indicates the distance to the zero point for the LMS400 distance
measurement.
Column details
Details on each marked column are displayed on the right beside the diagram, such as the
column number, the left and right border, the configured switching point (Z level), the value
determined and the status.