Online help
LMS400
Monitor
8011984/YSZ3/2016-02-04
© SICK AG · Germany · All rights reserved · Subject to change without notice
33
Chapter
5
How to display the curves as lines or dots:
Fig. 7:
Scan view
Select the L
INE
option.
The distance and energy data are displayed as a continuous line.
Select the P
OINTS
option.
The energy and distance data are displayed as individual dots.
How to save the scan data:
Select the E
NABLE
RECORDING
TO
FILE
option.
In the field underneath enter a path and file name or select these using the button
beside the field.
5.2
Display of the Level Control application
The results of the column evaluation are prepared graphically in the display for the
application Level Control. To obtain displayed results, you must start the application.
5.2.1
Start and stop of the application
In the A
PPLICATION
area you can start or stop the application Level Control for the LMS400.
How to start the application:
Lines
Points
Open in the P
ROJECT
TREE
, LMS400-XX00, M
ONITOR
the device page L
EVEL
C
ONTROL
V
IEW
.
In the A
PPLICATION
area, click the S
TART
button.
The column values can now be displayed in the V
IEW
area.