background image

8014640/ZMG2/2017-05-12 

• Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com

4

LeCtor62x | SICK

setup and function

NOTE

risk of damaging the swivel connector

¾

¾

the plug unit may be moved up to 180° from end 

point to end point of the stop. the eCo variant has 

no swivel connector.

Device structure Lector620 with swivel 

connector

Re

ad

y

Re

ad Diag

n

Re

sult

Te

achI

n

LE

D

Auto

-Setup

Data

Auto

fo

cu

s

LNK TX

Userdefine

d

300 200 100 70 40

100

0

[mm]

[%

]

1

2

3

5

a

4

1

6

7

8

9

ß

á

à

â

26.5

35.6

6

10

4.

8

21.5

26

43

71

17.44

Ø 10

Fig. 6:  Structure of Lector620 Professional, High Speed, 

DPM Plus and oCr. All dimensions in mm.

1. 

M5 blind tapped holes, 5 mm deep (4 x), for mounting the 

Lector620

2. 

“ethernet” connection (female connector, M12, 4-pin, 

D-coded)

3. 

“Power/Serial Data/CAN/I/o” connection (male connec-

tor , M12, 17-pin, A-coded)

4. 

M5 sliding nuts, 5 mm deep (2 x), for mounting the 

Lector620 (alternative)

5. 

Swivel connector

6. 

reading window

7. 

Function button (2 x)

8. 

Bar graph display

9. 

RGB LEDs for status indication (2 modes), 5 x

ß

 

Cover (flap)

à

 

USB port, female connector, Micro B type, 5-pin

á

 

Slot for microSD memory card

â

 

LeD for microSD memory card

Device structure icr620D-t51503  

(part number 1064256)

See downloadable dimensional drawing on the SICK 

product page in the web. Path:  

www.sick.com/Lector62x

 > Select device > tab “tech-

nical data” > Section “technical drawings”

Device structure Lector620 with cable outlet

Re

ad

y

Re

ad Diag

n

Re

sult

Te

achI

n

LE

D

Auto

-Setup

Data

Auto

fo

cu

s

LNK TX

Userdefine

d

300 200 100 70 40

100

0

[mm]

[%

]

1

2

1

3

4

5

6

8

7

9

26.5

35.6

6

10

4.

8

43

21.5

26

71

Ø 10

Fig. 7:  Structure of Lector620 eCo. All dimensions in mm.

1. 

M5 blind tapped holes, 5 mm deep (4 x), for mounting the 

Lector620

2. 

M5 sliding nuts, 5 mm deep (2 x), for mounting the 

Lector620 (alternative)

3. 

reading window

4. 

Function button (2 x)

5. 

Bar graph display

6. 

RGB LEDs for status indication (2 modes), 5 x

7. 

Cable (0.9 m) with male connector, D-Sub HD, 15-pin 

(“Power/Serial Data/CAN/I/o”)

8. 

Cover (flap)

9. 

USB port, female connector, Micro B type, 5-pin

Lighting unit

1

3

2

1

1

1

1

2

1

ECO variant

Fig. 8:  Lighting unit

1. 

Integrated lighting = 4 x LED (2 x left/2 x right);  

ECO variant: 2 x LED (2 x left)

2. 

Feed-back spot (e.g. for Good Read) = 1 x green LED

3. 

Aiming lasers for alignment, can be deactivated = 2 x red 

laser LeDs

the eCo variant has no aiming laser.

status indicators, functions

Ready

Read Diagn

Result

TeachIn

LED

Auto-Setup

Data

Autofocus

LNK TX

Userdefined

300

200

100

70

40

100

0

[mm]

[%]

O

O

O

O

O

Fig. 9:  LeD status indicators, function buttons and bar 

graph display

status indicators in read mode

Display

LeD

color

status

ready

O

Green

Device ready to read

O

red

Hardware or software error

result

O

Green

read operation successful

O

red

read operation unsuccessful

LeD

O

Green

read mode: Illumination on, 

internal reading gate open

Data

O

Yellow Data output via host interface

LnK tX

Ö

Green

Data traffic via Ethernet

= illuminated; 

Ö 

= flashing

tab. 3:  Status indicators in read mode

Status indicators in configuration mode

Display

LeD

color

status

read 

Diagn

O

Blue

test (reading diagnostics) 

selected

Ö

Blue

test started

teachin

O

Blue

teach-in selected (default: 

Match code)

Ö

Blue

teach-in started

O

Green

teach-in successful

O

red

teach-in unsuccessful

(match code default setting: 

unable to teach in any code)

auto-

setup

O

Blue

Auto-Setup selected

Ö

Blue

Auto-Setup started

O

Green

Auto-Setup successfully quit

O

Yellow Auto-Setup was partially suc-

cessful

O

red

Auto-Setup was unsuccessful

auto fo-

cus (not 

with 

the ecO 

variant)

O

Green

Function can be defined by 

user

O

Yellow Function can be defined by 

user

O

Blue

Function can be defined by 

user

O

red

Function can be defined by 

user

= illuminated; 

Ö 

= flashing

tab. 4:  Status indicators in configuration mode

audible status indicator (beeper)
Signals a selectable event (default: Good read). User 

operations are accompanied by a series of sounds. 

Can be switched off

Functions

For information on operation of functions, see 

&

 

Online help for device in configuration software 

SOPAS ET.

read Diagn (read diagnosis)
Percentage analysis: the device records a series of 

images and uses the current reading performance 

settings to decode them. the read rate of the last 10 

read operations is displayed in % using the bar graph.

Summary of Contents for Lector620

Page 1: ...e emphasis here is on the availability of products and their features SICK AG always assumes that the integrity and confidentiality of the data and rights affected by the use of these prod ucts will be ensured by the customer In all cases appropriate security measures such as network separation firewalls virus protection and patch management must be taken by the customer on the basis of the situat...

Page 2: ...n electrical systems Electrical connections between the device and other devices may only be created or disconnected when there is no power to the system Otherwise the devices may be damaged When using connecting or extension cables with an open end make sure that bare wire ends are not touching risk of short circuit when the supply volt age is switched on Wires must be appropriately insulated fro...

Page 3: ...ware as well as current device description files sdd from the online product page for the software by following the instructions provided there www sick com SOPAS_ET In this case select the Complete option as selected by the installation wizard Administrator rights may be required on the PC to install the software 2 When starting select the required user interface Standard user interface for stand...

Page 4: ...ghting unit 1 3 2 1 1 1 1 2 1 ECO variant Fig 8 Lighting unit 1 Integrated lighting 4 x LED 2 x left 2 x right ECO variant 2 x LED 2 x left 2 Feed back spot e g for Good Read 1 x green LED 3 Aiming lasers for alignment can be deactivated 2 x red laser LEDs The ECO variant has no aiming laser Status indicators functions Ready Read Diagn Result TeachIn LED Auto Setup Data Autofocus LNK TX Userdefine...

Page 5: ... the slot until it locks into place 5 Screw the cover on tight Transport and storage Transport and store the device in its original packag ing ensuring that the protective caps or plugs have been screwed onto the electrical connections Do not store outdoors To ensure that any residual moisture present can escape do not store the device in airtight containers Do not expose to aggressive media e g s...

Page 6: ...unit See Type code on page 7 Sensor resolu tion See Type code on page 7 Image sensor type See Type code on page 7 Scanning frequency at full resolution 60 Hz at WVGA resolution With ECO variant 25 Hz at WVGA resolution Ambient light immunity 2 000 lx on code Bar code types 1D 2 5 Interleaved Codabar Code 128 Code 32 Code 39 Code 93 GS1 DataBar GS1 128 EAN 128 Pharmacode UPC GTIN EAN Type Lector620...

Page 7: ...equired USB USB Supply voltage VS Fig 13 Lector62x ECO with cable outlet Type Lector620 ICR620x xxxxxx Electrical pro tection class III DIN EN 60950 1 2006 04 A11 2009 03 A1 2010 03 A12 2011 02 A2 2013 08 Enclosure rating See Type code on page 7 According to EN 60529 2000 09 Maintaining the enclosure rat ing See For your safety on page 1 EMC Electromagnetic immunity EN 61000 6 2 2005 08 01 Radiate...

Page 8: ...connector M12 4 pin D coded Pin Signal Signal Signal 1 GND Supply voltage VS TX 2 Supply voltage VS RxD RS 232 Aux RX 3 CAN L TxD RS 232 Aux TX 4 CAN H Sensor 2 RX 5 TD RS 422 Host GND 6 TD RS 422 Host TxD RS 232 Host RD RS 422 Host 7 TxD RS 232 Aux RD RS 422 Host RxD RS 232 Host 8 RxD RS 232 Aux TD RS 422 Host 9 SensGND TD RS 422 Host TxD RS 232 Host 10 Sensor 1 switching input CAN H 11 RD RS 422...

Reviews: