Chapter
10
Operating instructions
ICR 84x Image Code Reader
10-30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 961/0000/10-05-2005
Appendix
6.
Start Windows and “CLV Setup“ on your PC
(
Chapter 10.3.3 “Starting “CLV Setup““,
)
.
7.
Upload the parameter set that was last stored permanently on the ICR.
CLV Setup displays the current values on the tabs.
8.
If you have not already done so, save the parameter set as a configuration file “*.scl“ in
CLV Setup.
a) Dynamic teach-in procedure
Configuring the dynamic teach-in procedure:
•
Accompanying measure: change the reading pulse for teach-in
1.
Select the D
EVICE
C
ONFIGURATION
tab.
2.
From the A
SSIGNMENT
drop-down list in the S
ENSOR
2 group, choose the M
ATCHCODE
T
EACH
-
IN
option.
3.
Click the M
ATCH
C
ODE
P
ARAMETERS
button.
The M
ATCH
C
ODE
P
ARAMETERS
tab is then displayed.
4.
If necessary proceed as follows to activate the output filter in the C
ODE
A
CTIVE
group:
– Click the C
ODE
#1 checkbox.
– Click the F
ILTER
FOR
H
OST
O
UTPUT
checkbox.
– Click the C
ODE
#1 checkbox again.
The code comparison is now no longer permanently activated. The output filter,
however, remains active.
5.
Select the D
EVICE
C
ONFIGURATION
tab.
6.
Click the R
EADING
T
RIGGER
P
ARAMETERS
button.
7.
Click the S
ERIAL
I
NTERFACE
radio button in the S
TART
OF
READING
INTERVAL
group.
8.
Select the D
EVICE
C
ONFIGURATION
tab.
9.
Click the R
ESULT
O
UTPUT
P
ARAMETER
button.
10. In the dialog box under R
ESULT
F
UNCTIONS
, choose the M
ATCH
1 option for Result 2 (LED
“Result“) in the drop-down list.
11. If 2-D codes (DataMatrix ECC 200) are being read, continue with Step
12. When reading bar codes, select the C
ODE
C
ONFIGURATION
tab.
13. Activate the bar code type of the match code in the 1D-S
YMBOLOGIES
group.
14. Click the corresponding E
DIT
button.
The tab of the selected code types is then displayed.
15. In the C
ODE
L
ENGTH
group, click the F
REE
radio button.
16. Perform a download to the ICR. This is done by clicking
in the toolbar.
The D
OWNLOAD
P
ARAMETER
dialog box is displayed.
17. Confirm the dialog box by selecting the P
ERMANENT
save option.
Carrying out the dynamic teach-in procedure:
1.
Click
in the toolbar.
The Terminal Emulator is launched. The ICR is in Reading mode.
2.
Close the switch
to connect the power supply to the “Sensor 2“ switching input.
3.
Click P
ARAMETERIZE
under D
EVICE
M
ODE
.
The ICR switches to Parameter mode.
4.
Click R
EADING
M
ODE
under D
EVICE
M
ODE
.
The ICR returns to Reading mode and polls the condition of the “Sensor 2“ switching
input. It also activates code comparison at this time.