Chapter
10
Operating instructions
ICR 84x Image Code Reader
10-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 961/0000/10-05-2005
Appendix
10.3.3
Starting “CLV Setup“
The “CLV Setup“ program is launched with the following default settings:
Data communication via the auxiliary interface (RS 232):
1.
Switch on the PC and start Windows
2.
Choose CLV Setup from the Start menu.
The introductory dialog box is displayed after the identifier for the SICK software.
3.
Confirm the initial screen with “OK“.
CLV Setup then checks whether an ICR is connected to the
COM 1
port on the PC and
whether the communication parameters on the PC match those on the ICR. If this is the
case, the
“Connected“
status is displayed with the ICR specification on the bottom, right-
hand side in the status bar. The detected device type is displayed in the toolbar in the
D
EVICE
drop-down list (in this case: ICR 84x).
The software then loads the internal device description of the ICR and the defaults settings
of the parameter values from its database and displays these on the tabs. The software
then copies the current parameter set from the memory (RAM) of the ICR. This is displayed
on the tabs instead of the default settings.
You can edit the current parameter set on the tabs. The default values are displayed when
the device is used for the first time.
Troubleshooting
If CLV Setup cannot establish a connection with the ICR, it displays „
No connection“
in the
status field on the bottom, right-hand side. There are two possible causes for this. The ICR
is not connected or the communication parameters of the ICR do not match those of the
PC. In this case, CLV Setup enters the device type of the device it last communicated with
in the D
EVICE
drop-down list on the toolbar. The default setting is CLV 41x the first time CLV
Setup is started. The software then loads the internal device description for this type and
the default settings of the parameter values from its database and displays these on the
tabs.
Communication
COM 1 (RS 232), 9,600 bd, 8 data bits, 1 stop bit, no parity
Transmit control character
Start: STX, Stop: ETX
Receive control character
Start: STX, Stop: ETX
Unit of measure
Metric (depending on the selected installation)
Browser
user dependent
Language
As selected for the installation
Company name
As entered for the installation
User name
As entered for the installation
Establish connection to ICR
automatically
At startup: Yes
On scanner selection: Yes
When the Terminal Emulator is started/closed: Yes
Initial screen
Yes
Storage confirmation prompt
Yes
Last type selected
CLV 41x
File storage location
“data“ (configuration files for ICR)
Table 10-2: Default settings in CLV Setup (extract)