0
Sensing range
2
650
1
2
3
Sensing range typ. max.
8
(0.31)
16
(0.63)
24
(0.94)
32
(1.26)
40
(1.57)
35
28
1
2
320
35
29
35
30
1
Sensing range in white, 90 % remission
2
Sensing range on gray, 18 % remission
3
Sensing range on black, 6 % remission
Distance in mm (inch)
Figure 6: Sensing range 30 mm
4
5
6
Figure 7: Description of the sensing range areas
Table 3: Sensing range areas
Sensing
range /
object
color
-Xxx4x
6
-Xxx1x
6
-Xxx3x
6
4
0 ... 1 mm
0 ... 1 mm
0 ... 1 mm
5
/
1
1 ... 8 mm
1 mm
1 ... 15 mm
3 mm
1 ... 30 mm
5 mm
5
/
2
2 ... 8 mm
1 mm
2 ... 15 mm
3 mm
2 ... 29 mm
6 mm
5
/
3
2 ... 8 mm
1 mm
2 ... 15 mm
3 mm
2 ... 28 mm
7 mm
Use
to check the function. If the switching output fails to behave
in accordance with the table, check the application conditions. See section Fault diag‐
nosis.
7.3
Setting
Sensing range setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
Table 4: Sensing range setting
COMMISSIONING
7
8023328.1C14/2021-06-28 | SICK
O P E R A T I N G I N S T R U C T I O N | GTB2 Flat
9
Subject to change without notice