TECHNICAL DATA
15
Technical data
DUSTHUNTER SP100 Ex-2K system (Zone 1/21)
Table 27: Technical data, complete system
Measured variable
Scattered light intensity
(dust concentration output in mg/m³ after gravimetric comparison measurement)
Measuring principle
Scattered light measurement (forward dispersion)
Spectral range
640 nm … 660 nm
Laser, protection class 2, capacity <1 mW
Measuring range (freely
adjustable)
Dust concentration
0...5 mg/m³ / 0...500 mg/m³
Higher measuring ranges on request
Certified measuring ranges
Scattered light intensity
0...7.5 mg/m³
(additional measuring ranges 0...10, 0...15, 0...50, 0...100, 0...200, 0...500 mg/m³)
Response time (t90)
1 … 600 seconds
Freely adjustable
Precision
≤
2%
of measuring range end value
Process temperature
Standard version
DHSP-T2xxxxEx2K
High temperature version
DHSP-T4xxxxEx2K
-40 °C ... +220 °C
-40 °C ... +400 °C
Process pressure
With instrument air
(from customer)
0 hPa... +3000 hPa
Process gas moisture
Non-condensing
Internal duct diameter
≥
0.25 m
Compliances
Approved for systems requiring approval:
2001/80 /EC (13. BlmSchV)
2000/76/EC (17. BlmSchV)
27. BlmSchV
TA-Luft
EN 15267
EN 14181
2010/75/EU
U.S. EPA PS-11 compliant
Electrical safety
CE
Control functions
Automatic self-test (linearity, contamination, drift, aging)
Contamination limits: At 30% warning, at 40% malfunction
Manual linearity test via reference filter