8.3.14
Configuring the switching input
NOTE
The digital input is deactivated ex works. When a digital input is not in use, it is to be
deactivated to ensure the highest possible level of interference immunity.
Various device functions can be activated using the switching input.
Parameter
Factory setting
Deactivated:
Deactivate the switching input
active
Measurement laser off:
Switching signal deactivates the measurement laser
deactivated
Alignment laser to:
Switching signal activates the alignment laser
deactivated
Preset:
Switching the input signal from deactivated to activated sets the
output distance value to the preset value entered under “In1: Pre‐
set” (initialization position). The automatically calculated distance
offset value is permanently saved in the device. Triggering the
preset overwrites a previously parameterized distance offset. The
preset should be triggered during a standstill or at very low speed.
The following applies at the initialization position:
Preset = output distance value = measured distance value x
measuring dir distance offset
Preset value: -1,500 m ... 1,500 m (factory setting: 0 m)
disabled
8.3.15
Defining the active state for digital input
The active state describes the relationship between the physical input signal (high or
low) and the logical status of the input signal (active or inactive).
Parameter
Factory setting
LOW:
Input potential for the active state: low voltage
LOW
HIGH:
Input potential for the active state: high voltage
8
REFERENCE
78
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK