8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 29
Operating instructions Distance measuring device DL100 Pro – RS-422
Mounting
6.7
Mount alignment bracket and distance measuring device
The distance measuring device is mounted by the optional alignment
bracket.
→
For dimensions and item number, see page 81, chapter 14.1.
Observe the follwong items:
• Mounting notes:
→
• The operation must be accessible.
1. Mount alignment bracket across the four oblong holes. The alignment
bracket is suitable for mounting to horizontal and vertical levels.
Fig. 12: Mount alignment bracket
1 Mounting screw M5
2 Alignment bracket
2. Turn out knurled screw from the alignment bracket.
3. Move distance measuring device into the alignment bracket.