background image

S U P P L E M E N T A R Y   O P E R A T I N G   I N S T R U C T I O N S

Title Page

Description
Operating Functions
Technical Data

Analyzer Module DEFOR
for Series GMS800

Summary of Contents for DEFOR

Page 1: ...S U P P L E M E N T AR Y O P E R A T I N G I N S T RU C T I O N S Title Page Description Operating Functions Technical Data Analyzer Module DEFOR for Series GMS800...

Page 2: ...of doubt Legal information Subject to change without notice SICK AG All rights reserved Glossary Warning Symbols Signal Words CAUTION Hazard or unsafe practice which could result in personal injury or...

Page 3: ...s cuvette 12 4 Functions in SOPAS ET 13 4 1 Menu tree in SOPAS ET 14 4 2 Explanation of the menus in SOPAS ET 16 4 3 Explanation of functions 18 4 3 1 Logbook in SOPAS ET 18 4 3 2 Upload data synchron...

Page 4: ...Contents 4 DEFOR Supplementary Operating Instructions 8013029 V2 0 SICK AG...

Page 5: ...nformation DEFOR Supplementary Operating Instructions 8013029 V2 0 SICK AG 5 Subject to change without notice DEFOR 1 Important Information Operating information Application limitations Additional doc...

Page 6: ...ering gas creates a constant devia tion from the true measured value every time constant characteristic curve offset The deviation varies accordingly when the interfering gas concentration fluctuates...

Page 7: ...Product Description DEFOR Supplementary Operating Instructions 8013029 V2 0 SICK AG 7 Subject to change without notice DEFOR 2 Product Description Measuring principle Measuring ranges...

Page 8: ...ple M M M M M M M IFC IFC UVRAS UVRAS 1 UV lamp 2 Filter wheel unit 2a Filter wheel 1 2b Filter wheel 2 3 Collimator lens 4 Beam splitter 5 Mirror 6 Sample cuvette 1 1 Length 0 4 1 5 5 6 21 80 300 mm...

Page 9: ...relevant gas into the beam path filter wheel 2b Both measuring methods are combined for joint measurement of NO and other gases both filter wheels 2a 2b are used The physical state of the measuring sy...

Page 10: ...cally requires automated zero gas feed 2 2 2 Process cuvette The versions with process cuvette are intended for applications with dangerous sample gases where it must be ensured the sample gas does no...

Page 11: ...allation Information DEFOR Supplementary Operating Instructions 8013029 V2 0 SICK AG 11 Subject to change without notice DEFOR 3 Installation Information Sample gas feed Purge gas feed for process cuv...

Page 12: ...pply for GMS800 Suitable purge gas Chemically neutral gas inert gas or gas mixture suitable for dilut ing and transporting the measured gas without danger 2 Feed the purge gas through the purge gas in...

Page 13: ...ithout notice DEFOR 4 Functions in SOPAS ET Menu functions in the PC program SOPAS ET Menu tree Explanations Instructions for the PC program SOPAS ET User Information for the pro gram Exemplary menu r...

Page 14: ...18 4 3 1 Operating hours Lamp h p 16 5 Measuring component 1 Name unit Component p 16 1 Unit p 16 2 State Failure Maintenance request p 16 4 Function s active Uncertain state Validation measurement Q...

Page 15: ...t results Adjustment result Zero point Reference point Drifts Zero point p 17 18 Reference point Delete results Delete p 20 4 3 5 Measuring component 2 1 Measuring component 10 1 Maintenance Maintenan...

Page 16: ...UV lamp evaluated automatically 7 UV lamp service life p 26 5 7 7 Failure UV lamp status evaluation of intensity OK full intensity Maintenance UV lamp replacement recommended Uncertain correct measuri...

Page 17: ...ntenance work 21 User settings Backup save a copy of the actual module settings Restore overwrite the actual module settings with the saved copy 1 22 Factory settings Overwrite the actual module setti...

Page 18: ...omatically to SOPAS ET after settings for a module have been changed with the menu functions of the control unit SOPAS ET continues using the previous data To transfer the current data of a module to...

Page 19: ...nuous minor measured value fluctuations but rapid measured value changes are still displayed without delay Dynamic behavior is determined with the Thresh old parameter When the measured values change...

Page 20: ...ains valid 4 3 5 Deleting adjustment results The Delete results function deletes all determined drift values of a measuring compo nent Drift limit values then refer to new drift values The data of the...

Page 21: ...ual adjustment of each shown measuring component and each measuring range Information concerning purpose prerequisites and frequency of adjustments Operat ing Instructions Series GMS800 Programming of...

Page 22: ...22 DEFOR Supplementary Operating Instructions 8013029 V2 0 SICK AG Functions in SOPAS ET Subject to change without notice...

Page 23: ...ical Data DEFOR Supplementary Operating Instructions 8013029 V2 0 SICK AG 23 Subject to change without notice DEFOR 5 Technical Data Ambient conditions Sample gas specifications Metrological specifica...

Page 24: ...ring ranges 4 4 Valid for measuring ranges 2x smallest measuring range 1 of measurement span Linearity deviation 1 of measurement span Zero point drift Standard measuring ranges 1 of measurement span...

Page 25: ...es in the sample gas Sample gas should be free from dust and aerosols 4 4 On the sample gas inlet Allowable sample gas pressure 5 5 Relative to the ambient atmospheric air pressure 200 300 hPa 0 2 0 3...

Page 26: ...100 CS2 50 170 30 H2S 25 40 100 NH3 50 40 100 NO 10 15 50 100 NO2 50 10 2 2 For operation in air conditioned environment 2 C temperature deviation and daily zero point adjustment 105 20 2 50 100 SO2...

Page 27: ...Technical Data DEFOR Supplementary Operating Instructions 8013029 V2 0 SICK AG 27 Subject to change without notice Empty page...

Page 28: ...l 9 Flow volume flow Purge gas 25 Sample gas 25 Function s active 16 Functions in SOPAS ET 13 G Gas filter correlation 9 Glossary 2 H Hardware version display 15 I ID numbers 15 Identification 15 IFC...

Page 29: ...PAS ET important information 18 SOPAS ET 13 Start value display 16 Stop bits 16 Symbols explanation 2 T Target display 16 Technical data 23 Materials with sample gas contact 25 Measuring ranges 26 Met...

Page 30: ...G Waldkirch Germany www sick com 8013029 V2 0 2012 12 Subject to change without notice SICK worldwide You will find our local subsidiary or agency at www sick com Your local sales and service partner...