7
Technical data
7.1
Data sheet
NOTE
The following table only contains details on the safety light curtain that are not included
in the underlying operating instructions.
Table 2: General system data
Minimum
Typical
Maximum
Protective field height, depending on
type
600, 900, and 1,200 mm
Resolution (detection capability)
20 mm
Protective field width
0 m … 15.9 m
0 m … 17.6 m
1)
Enclosure rating (EN 60529)
IP 66
2)
Equipment group/category II
X
II 2 G Ex db IIB T6 Gb
X
II 2 D Ex tb IIIC T56°C Db
Ex db IIB T6
Ex tb IIIC T56°C Db IP6X
Weight
Depending on the protective field height,
1)
If you are using the full protective field width, check to see if the orange LED lights up (cleaning or align‐
ment necessary). The system still has a reserve of 30
%.
2)
In order to achieve enclosure rating IP 66, washers must be used for the fixing screws on the enclosure
cover.
7.2
Table of weights
Table 3: Weight of sender and receiver
Protective field height [mm]
Weight [kg]
1)
s
Sender
r
Receiver
600
29.92
29.95
900
38.57
38.6
1200
47.22
47.25
1)
Tolerance: ± 50 g.
7
TECHNICAL DATA
24
O P E R A T I N G I N S T R U C T I O N S | C4000 Fusion Ex
8022867/2019-03-04 | SICK