7
OPERATION
70
8027513/V1-0/2022-03|SICK
O P E R A T I N G I N S T R U C T I O N S | MDA Vision
Subject to change without notice
7.7.3
Object not placed in the reading field
•
Measured value determination is not started despite successful code reading.
•
The object is not in the measuring range or touches the edge of the measuring field.
•
The
Place object centered on scale for measurement
appears in the status bar.
•
Parts of the object are not in the field of view of the Visionary-S 3D camera.
•
Dimensional values cannot be determined.
▸
Move object on the scale so that all object areas are in the Visionary-S field of view.
•
As soon as the identified object has been correctly placed on the scale, weight and
dimension values are determined and transmitted if a network connection is
established.
Error description
Fault cause
Solution