10
Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
Please note: This documentation may contain further technical data.
10.1
Features
Variant
TiM8xx DistanceGuard
Measurement principle
HDDM+
Application
Outdoor
Light source
Infrared (wavelength 850 nm, max. pulse power 880 mW, max.
pulse width 5 ns, pulse frequency 1,500 kHz)
Laser class
1 (IEC 60825-1:2014, EN 60825-1:2014)
Aperture angle
270° (horizontal)
Scanning frequency
15 Hz
Angular resolution
0.33°
Working range
0.25 m ... 10 m
10.2
Performance
Variant
TiM8xx DistanceGuard
Response time
typ. 67 ms
Detectable object shape
Almost any
Systematic error
± 60 mm
1
Statistical error
20 mm
1
Integrated application
DistanceGuard
Maximum number of peo‐
ple in the region of interest
20
Maximum surface area of
the region of interest
235 m²
1
Typical value at room temperature and up to a sensing range of 10 m at 90% remission, real value
depends on ambient conditions, temperature drift: 0.5 mm/K
10.3
Interfaces
Variant
TiM8xx DistanceGuard
Ethernet
TCP/IP
Max. data transmission rate: 10 Mbit and 100 Mbit
Length of cable: max. 100 m
USB
Type: Micro-USB
Function: Diagnostics, Ethernet settings
Digital inputs
4 (reserved)
Digital outputs
4 (PNP; OUT1 = minimum distance undercut, OUT2 = maximum
number of people exceeded, OUT3 = device overloaded, OUT4 =
reserved), I
out
≤ 100 mA
TECHNICAL DATA
10
8025963//2020-08-05 | SICK
O P E R A T I N G I N S T R U C T I O N S | TiM8xx DistanceGuard
35
Subject to change without notice