3
SYSTEM DESCRIPTION
42
8020776/12AX / 2019-05-31|SICK
O P E R A T I N G I N S T R U C T I O N S | Free Flow Profiler
Subject to change without notice
3.5
Project planning
Reliable and problem-free use of the profiling system depends on a number of different
factors.
3.5.1
General system requirements
To operate the profiling system, the following are required:
•
A supply voltage of 24 V DC (12 V DC to 36 V DC) for the Traffic Controller FPS.
•
A supply voltage of 19.2 V to 28.8 V for the LMS511 SE 2D LiDAR sensor.
•
Customer computer with a TCP/IP data interface for setting up the system, processing
the measurement results further, and monitoring the system
•
If no Ethernet cables are purchased from SICK for the connection between the 2D
LiDAR sensor and Ethernet switch or between the Ethernet switch and Traffic Controller
FPS, or if no connectors have to be assembled, we recommend testing the cable quality
in accordance with CAT 5e (10/100 Mbit/s) requirements.
Requirements for the client computer
An up-to-date version of a web browser must be installed on the client computer. This
browser must support
HTML5
and
WebGL
.
Requirements for the customer network
The following ports must be open on the customer network:
•
Port 80 for TEMS Manager Web
•
Port 21 for FTP access (log files, vehicle files)
•
Port 40,000 to 45,000 for FTP data transfer
•
Port 123 for NTP time synchronization
•
Port 5900 for remote access via VNC
3.5.2
Requirements for vehicles
The profiling system can be used to measure all types of vehicle.
The vehicles must have the following properties:
Dimension
Min.
Max.
Length
1.0 m
30.0 m
Width
0.6 m
5.0 m
Height
0.6 m
5.0 m
Tab. 3: Project planning – Vehicle properties