•Power must be supplied by a differential protection device (RCD), with rated residual current 

beneath 30mA.

INSTALLATION AND USE

ATTENTION:

 disconnect all electric appliances before putting hands in water. Before plugging 

the device in, make sure it is damage free in all of its parts, especially the cable and plug. Take 

the product out of the box and undo the cable. 

1) Insert suction cups in their seats and rotate until certain they are properly fixed (fig. 2).  

2) Clean the glass and place the pump vertically, with knob facing upwards (fig. 3), applying pres

-

sure so suction cups adhere. Make sure the pump is completely immersed in water.

ATTENTION:

 to avoid vibration and resonances, DO NOT position the remaining sides of the 

device to the bottom or sides of the tank. 

3) Turn the knob, placed on top of the unit, clockwise to increase CO2 emission, counter clock-

wise to decrease it (fig. 4)

4) Plug the product to the power socket.

IMPORTANT: ADVISE FOR USE

• Emitting Co2 in water will cause an unavoidable decrease of the pH: it is advisable to monitor 

this value constantly. 

• During first use, the carbon cartridge is very sensative. Set it on  the MINIMUM setting for at 

least 24 hours, then measure CO2 concentration (see previous paragraph). If necessary, go up 

a notch (not more!) every 24 hours, until optimal levels are reached and maintained. 

• During electrolysis, the output, from the frontal grills, of CO2 mixed with water is invisible. The 

speed of the emission depends on the hardness and conductivity of water. CO2 should not 

be confused with bubbles of hydrogen (produced by electrolysis) that go towards the surface. 

Although the output of CO2 invisible to the human eye, this is the correct operation of the unit! 

IMPORTANT: 

remember that the abrupt interaction with the chemistry of water is a mistake that 

would compromise the delicate balance of the aquarium’s environment. 

• It’s possible to deactivate the pump during the night (when the absence of light hampers pho

-

tosynthesis), by simply connecting it to a timer (no need of complicated solenoids). Test to make 

sure the Ph level doesn’t increase inappropriately : if this happens, the pump MUST keep work

-

ing.

• The cartridge’s life can vary notably, depending on water hardness: a high concentration of 

minerals (“hard” water) helps conduciveness (measured in Micro-Siemens cm2 µS/cm2), con

-

suming carbon more quickly 

• It’s advisable to partially change water every month (20-25% of the tank’s volume),  using re

-

verse osmosis or demineralised water, in order to keep  the hardness of water stable;

• It is necessary to clean deposits from the tank’s lamps or light shields regularly and to substitute 

them once a year: low quality/ intensity light does not permit a correct photosynthesis in plants. 

• Excessive movement on the water surface reduces CO2 molecules. 

MAINTENANCE

ATTENTION: 

disconnect all electrical appliances from power supply before putting hands in 

water. 

1) Grasp the pump body and take it out of support (that remains attached to the glass); do not 

tug on cable to do this operation

2) Remove the transparent mixing cover, lifting it from pump body (fig: 5)

3) Remove the cartridge’s regulator and pre-filter;

Summary of Contents for CO2 Life

Page 1: ......

Page 2: ......

Page 3: ...Fig 2 Fig 4 Fig 6 Fig 3 Fig 5 Fig 7...

Page 4: ...ank or the fountain to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug A drip loop fig 1 should be arranged by the user for each cord connecting an aqu...

Page 5: ...serve all the important notices of the appliance 10 If an extension cord is necessary a cord with a proper rating should be used A cord rated for less amperes or watts than the appliance rating may ov...

Page 6: ...d une prise de courant pour emp cher l eau de d goutter sur la prise L utilisateur devrait faire une boucle d gouttement voir illustration 1 pour cha que cordon lectrique branch d un aquarium une pris...

Page 7: ...nt de le faire fonctionner 9 Lire et observer tous les avis importants sur l appareil 10 Si une rallonge lectrique est n cessaire vous assurer qu elle est d un calibre ad quat Un cordon lectrique de c...

Page 8: ...fore starting maintenance opera tions and putting hands in water If plug or cable are wet turn off the general power switch before unplugging the device Check that the voltage and frequency written on...

Page 9: ...ss and conductivity of water CO2 should not be confused with bubbles of hydrogen produced by electrolysis that go towards the surface Although the output of CO2 invisible to the human eye this is the...

Page 10: ...l under running water 9 Reassemble all the parts performing this sequence backwards paying attention that the closed part of the regulator faces behind otherwise you cannot close the transparent mixer...

Page 11: ...ann den Stecker ausziehen berpr fen ob die auf der technischen Etikette der Pumpe angegebene Netzspannung der jenigen des Anschlusses entspricht Bevor Sie das Ger t anschlie en berpr fen Sie es an all...

Page 12: ...lten werden W hrend der Elektrolyse des Kohlenstoffs mehr oder weniger schnell in Abh ngigkeit von der H rte Leitf higkeit des Wassers tritt das mit Wasser gemischte CO2 UNSICHTBAR aus den vorderen Gi...

Page 13: ...ebenen Ersatz aus 7 Reinigen Sie die feste Spindel VERSUCHEN SIE NICHT SIE HERAUSZUNEHMEN im Inneren des Rotorraumes mit einem in eine L sung aus Wasser und Essig oder Zitronensaft getr nkten Wattest...

Page 14: ...e prima di scollegare la spina Controllare che tensione e frequenza riportate nell etichetta dati tecnici corrispondano a quelle della propria rete elettrica Prima di alimentare il prodotto verificare...

Page 15: ...NON di pi ogni 24h fino al raggiungimento e al man tenimento dei valori OTTIMALI Durante il processo di elettrolisi del carbonio pi o meno velocemente in dipendenza dalla durezza conducibilit dell acq...

Page 16: ...rno della camera rotore utiliz zando un cotton fioc imbevuto in una soluzione di acqua e aceto o succo di limone 7 Togliere la spugnetta sul retro del prodotto e sciacquarla abbondantemente sotto l ac...

Page 17: ...al avant de d brancher la prise Veuillez v rifier que la tension indiqu e sur l tiquette corresponde bien celle de votre r seau lectrique Avant de proc der l alimentation du produit v rifier le parfai...

Page 18: ...ter d un trait PAS d avantage tous les 24h jusqu l obtention et le maintien des valeurs OPTIMALES Au cours du processus d lectrolyse du carbone plus ou moins rapidement selon la duret conductibilit de...

Page 19: ...fix NE PAS ESSAYER DE L EXTRAIRE l int rieur de la chambre du rotor en utilisant un coton Tige imbib d une solution d eau et de vinaigre ou de jus de citron 8 Enlever la petite ponge l arri re du pro...

Page 20: ...cable o enchufe estuvieran mojados desconecte el interruptor general de la electricidad antes de desconectar el enchufe Verificar que la tensi n indicada en la etiqueta t cnica de la bomba corresponda...

Page 21: ...ro y el mantenimiento de los valores PTIMOS Durante el proceso de electr lisis de carbono m s o menos velozmente dependiendo de la dureza conductividad del agua el CO2 sale INVISIBLEMENTE de las rejil...

Page 22: ...io indicado 7 Limpie el eje fijo NO INTENTE SACARLO del interior de la c mara del rotor utilizando un pedazo de algod n empapado en una soluci n de agua y vinagre o jugo de lim n 8 Quite la esponja de...

Page 23: ...qualquer aparelho que esteja dentro do aqu rio ou antes de mergulhar as m os na gua por qualquer raz o no caso do plugue ficar molhado desligue a rede el trica antes de tocar no cabo Certifique se qu...

Page 24: ...s valores MAIS ADEQUADOS Durante o processo de electr lise do carbono mais ou menos rapidamente dependendo da dureza condutibilidade da gua CO2 sai DE FORMA INVIS VEL das grelhas frontais mistura do c...

Page 25: ...tor esteja excessivamente gasto provocando um aumento de ru do substitu lo pelo de reposi o indicado 7 Limpar o pequeno eixo fixo N O TENTAR EXTRA LO no interior da c mara do rotor utili zando um coto...

Page 26: ...RU kH pH KH 1 CO2 Life CO2 Life 35 C CO2 600 CO2 life 1 DRIP LOOP...

Page 27: ...30 A 1 2 2 3 3 CO2 4 4 CO2 pH 24 CO2 24 CO2 pH 20 25...

Page 28: ...CO2 1 2 5 3 4 5 a 6 b 6 6 7 7 8 9 2002 96 EC 3...

Page 29: ...pcontact haalt Voordat u het product op de electriciteitsvoorziening aansluit dient u dit zorgvuldig te controle ren op eventuele beschadigingen in het bijzonder kabel en stekker De kabel en de stekke...

Page 30: ...ren verlaat de CO2 ONZICHTBAAR gemend met water het roostertje aan de voorkant laat u niet misleiden door eventuele belletjes die via het pijpje aan de bovenkant het apparaat verlaten en naar boven st...

Page 31: ...t behulp van een wattenstaafje gedrenkt in een oplossing van water met azijn of citroensap 8 Verwijder het sponsje van de achterzijde van het product en spoelt het zorgvuldig uit onder stromend water...

Page 32: ...r v dt slukkes for hovedkontakten f r stikket tages ud Tilse at apparatets elektriske data stemmer overens med Deres netv rk Inden produktet tilsluttes er det n dvendigt at afpr ve integreringen af al...

Page 33: ...fungere som beregnet selvom det ved f rste jekast umiddelbart ikke kan ses VIGTIGT glem ikke at en pludselig forandring af vandets kemiske v rdier vil v re en alvorlig fejl som vil have betydning for...

Page 34: ...nsparente l g KORREKT AFFALDSBORTSKAFFELSE AF DETTE PRODUKT ELEKTRISK ELETRO NISK UDSTYR M rket p dette produkt eller i den medf lgende dokumentation betyder at produktet ikke m bortskaffes sammen med...

Page 35: ......

Page 36: ...SICCE S p A Via V Emanuele 115 36050 Pozzoleone Vicenza ITALY www sicce com 80N162 A...

Reviews: