User’s Guide
15
Errors are indicated in sum, for example. If error 16 and error 2 occur, the display will indicate 18. If error 8 and
error 16 occur, the display will indicate 24, and so on.
Adjust chlorine production
The main indication of the equipment is the percentage of chlorine generation, which can be adjusted using the
keys found on the right of the display, indicated . The percentage can be set at: 100%, 80%, 60%, 40% and 20% of
full capacity.
BOOST - TURBO function
This function causes the Chlorine Generator to operate at 100% production for 24 hours. The time in this function
is counted by operating hours, not continuous hours. For example, if the generator runs 8 hours a day, it will
run at 100% for 3 days (24h/8h = 3). At the end of 24 hours, chlorine generation returns to the last programmed
percentage.
To activate the boost function, just press the (T) key to the left of the display. To monitor the time remaining for the
function to end, simply press the F key, the display will indicate “BST” and then the decreasing time from 24 to 0.
To return to the generation percentage indication, simply press the “F” button and with the arrows navigate to the
indication of % of generation.
The generation of chlorine in this equipment is constant, that is, it does not depend on the amount of salt in the
water. Just needing to be between 2800 and 5000 PPM.
Flow Sensor
The Chlorine Generator has a flow sensor that, only from a minimum flow of water, the generation is started. Thus,
even if the equipment is energized and the generation percentage is programmed, production will only start when
there is water flowing through the pipeline.
Indication Display
Settings
Features
ERROR INDICATION
CODE
ERROR
CAUSE
1
Short Circuit in Cell
The cell may be short circuited.
Excess salt.
2
Open Cell
Electrical connection between controller and cell, broken.
Little salt in the water.
Disconnected cell.
4
Controller Overheating
Electronic controller is overheated.
Very hot environment.
Request a lot of power.
8
Excessive Power
Requested
Need a lot of power in the cell.
Little salt in the water.
16
Problem With
Temperature Sensors
Problem with water temperature sensor.
Problem with CPU temperature sensor.
Summary of Contents for CLARIPUR SG20
Page 1: ...CHLORINE GENERATOR CLARIPUR SG20 E SG35 USER S GUIDE English 1 Espa ol 23...
Page 2: ...2 User s Guide...
Page 22: ...22 Manual del usuario...
Page 23: ...Manual del usuario 23 GENERADOR DE CLORO CLARIPUR SG20 E SG35 MANUAL DEL USUARIO...
Page 24: ...24 Manual del usuario...
Page 44: ...44 Manual del usuario...
Page 45: ...Manual del usuario 45...