40
Open window detection:
This heater is equipped with an open window detection function. If our control system detects that
the room temperature decreases dramatically in short period when the heater is in the heating
status, it will recognize that a window is open. The window sign on the screen will start to flash
and the heater will power off for 30 minutes and get back to the previous setting automatically
after 30 minutes. You can deactivate and activate this function by long pressing for 5 seconds
the “-” button, and the open window sign on the screen will disappear and appear accordingly.
Temperature calibration
Long press “+” button for 5 seconds to enter the temperature calibration, adjust the number by
pressing “-” or “+” button, the calibration ranges from -5 to +5 degrees.
Activate/deactivate WIFI function
Long press “Timer” button for 10 seconds to deactivate the WIFI function of this heater and the
WIFI sign on the screen will disappear, long press “Timer” button for 10 seconds to activate it on
again.
Manual control:
To enter the manual mode, activate the power switch, press power button to power on the heater
and the “M” sign will show on the screen. Now the heater operates in the manual mode, adjust
your desired temperature by pressing “-” or “+” button, 2 seconds later the screen will retain to the
reading of current room temperature.
If you would like to set up the timer, press timer button and “00H” will appear on the screen and
you can set the timer by press “-” and “+” button to start the count-down timer.
IMPORTANT
Please note that only 2.4 GHz networks are supported!
Transmitting power: max. 100 mW