background image

911-439  Rev. G   5/99 

Page: 2 of 4 

 

 

6. 

Connect the tubing from the potable water tank to the inlet fitting.  The regulated city water line 

(if used) 

is 

connected with the swivel barb fitting

*

 to the threaded port at the bottom of the pump. 

DO NOT 

OVER-TIGHTEN!  HAND TIGHTEN ONLY!

  Secure the tubing with hose clamps

*

.  If the city water 

feature is not being used, install the threaded seal cap*.  

DO NOT OVER-TIGHTEN!  HAND 

TIGHTEN ONLY! 

7. 

Install the pump back into the hole and fasten in place.  

DO NOT

 over tighten the screws.  Doing so 

can distort the plastic bosses creating difficulty when snapping the trim plate in place. 

8. Perform a visual inspection of the installation before snapping the trim plate into position.

  To 

install the spout, align marks on spout and trim plate.  Press spout into the hole, and turn to the 
forward position.  Test the pump for proper operation and check tubing for leaks.  Remove and 
properly discard spout label. 

*

 supplied with after market pump 

#

150-001-00 

OPERATION

 

A.

 Water from Tank:  Fill water tank.  Pump the piston up and down.  Make sure all connections are tight. 

B.

 City Water:  ON:  Turn handle counterclockwise 1/4 turn.  OFF:  Return handle clockwise 1/4 turn. 

SANITIZING

 

Mix into solution, ½ ounce of common household bleach for every gallon of potable water tank capacity 
[liter 

 1 ml] and then fill the tank completely.  Operate the pump until the chlorine odor is detected.  

Allow the solution to have a 4-hour contact time, and then drain the holding tank.  Refill the tank and 
operate pump until the line is flushed clear of solution. 

WINTERIZING 

CAUTION:  DO NOT 

use propylene glycol based anti-freeze fluids.  

Never

 allow water freeze in pump. 

To winterize the pump, simply drain the holding tank.  Operate the pump until all water is flushed from 
the lines.  Remove the city water inlet fitting or threaded cap and collect the water that drains out.  
Operate the pump several strokes then reinstall the city water fitting or cap.  

Make sure pump is 

thawed before using!

 

Water Wizard

 

LIMITED WARRANTY

 

 

SHURflo warrants the 

Water Wizard

 hand pump to be free from material and workmanship defects (under normal 

use and service) for a period of one (1) year from the date of manufacture, or one (1) year of use, with proof of 
purchase.  In no case will the terms of this limited warranty extend beyond two years from the date of manufacture. 

Warranty claims may be resolved by the nearest authorized dealer service center, or by a SHURflo service center.  
All returns are to be shipped with charges pre-paid.  Package all returns carefully.  SHURflo will not be responsible 
for freight damage incurred during shipping. 

For complete warranty details refer to SHURflo Service Bulletin #1041. 
 
 
 
 
 

 

!

ISO Certified Facility 

SHURflo reserves the right to update specifications, prices, or make substitutions. 

SHURflo 

!

!

!

!

 

12650 Westminster Ave. 

Santa Ana, CA  92706-2100 

(800) 854-3218  (714) 554-7709  

FAX  (714) 554-4721 

Shipping/UPS:

 12650 Westminster 
Ave. 

Garden Grove, CA   92843 

SHURflo East 

52748 Park Six Court 

Elkhart, IN  46514-5427 

((800) 762-8094   (219) 262-0478 

FAX  (219) 264-2169 

http://www.shurflo.com 

© 1999   

 

SHURflo Ltd.  

Unit 5  Sterling Park 

Gatwick Road, Crawley 

West Sussex, RH10 2QT 

United Kingdom 

+44 1293 424000 

FAX  +44 1293 421880

 

 

Reviews: