background image

PUMP WILL NOT START/ BLOWS CIRCUIT:

• 

Electrical connections, fuse or breaker, main switch, and ground 
connection.

• 

Is the motor hot? Thermal breaker may have triggered; it will reset 
when cool.

• 

Is voltage present at the switch?  Bypass the pressure switch.
Does the pump operate? 

• 

Charging System for correct voltage (±10%) and good ground. 

• 

For an open or grounded circuit, or motor; or improperly sized 
wire.

• 

For seized or locked diaphragm assembly (water frozen?).

WILL NOT PRIME/SPUTTERS: 

(No discharge/Motor runs)

• 

Is the strainer clogged with debris?

• 

Is there water in the tank, or has air collected in the hot water 
heater?

• 

Is the inlet tubing/plumbing sucking in air at plumbing connections
(vacuum leak)?

• 

Is inlet/outlet plumbing severely restricted or kinked?  Restrictive 
valves?

• 

Proper voltage with the pump operating  (±10%).

• 

For debris in pump inlet/outlet valves or swollen/dry valves. 

• 

Pump housing for cracks or loose drive assembly screws.

RAPID CYCLING: 

• 

For restrictive plumbing and flow restrictions in faucets/shower 
heads.

• 

Water filter/purifier should be on separate feed line.

• 

Shut-off pressure set too low.

PUMP WILL NOT SHUT-OFF / RUNS WHEN FAUCET IS CLOSED: 

• 

Output side (pressure) plumbing for leaks, and inspect for leaky valves 
or toilet. 

• 

For air trapped in outlet side (water heater) or pump head.

• 

For correct voltage to pump (±10%).

• 

For loose drive assembly or pump head screws.

• 

Are the valves held open by debris or is the rubber swollen?

• 

Pressure switch operation.  By -pass set higher than shut -off

NOISY OR ROUGH OPERATION:

• 

For plumbing which may have vibrated loose.

• 

For a restricted inlet (clogged strainer, kinked hose, restrictive 
valves).

• 

Is the pump plumbed with rigid pipe causing noise to transmit?

• 

Does the mounting surface amplify noise (flexible)?  Does it bang 
like a drum?

• 

For mounting feet that are loose or are compressed too tight.

• 

For air in the system. Check all fixtures for air and bleed system.

• 

The motor with pump head removed. Is noise from motor or pump 
head?

LEAKS FROM PUMP HEAD OR SWITCH:

• 

For loose screws at switch, by -pass or pump head.

• 

Switch diaphragm ruptured or pinched.

• 

For punctured diaphragm if water is present in the drive    assembly.

Troubleshooting
Vibration induced by driving can loosen plumbing, strainers and pump hardware. Check for system
components that are loose. Also, refer to the chart below for trouble-shooting tips.

55 psi models: part kits 

PSI/Bar

GPM [LPM]

Amps

0/0

3.0 [11.3]

2.8

10/0.7

2.3 [8.7]

3.2

20/1.4

1.9 [7.2]

4.2

30/2.1

1.6 [6.0]

5.1

40/2.8

1.4 [5.3]

6.1

50/3.4

0.8 [3.0]

6.8

55/3.8

0

7.5

Typical Performance

1

 

2

 

3

 

4

 

LIMITED WARRANTY

SHURflo warrants its aftermarket retail 4008 series potable water pumps to be free from material and workmanship defects under normal use and service for 2 

years  from  the  date  of  purchase  with  purchase  receipt  or  2  years  from  the  date  of  manufacture  indicated  on  the  motor  nameplate  if  no  purchase  receipt  is
available,  as  outlined  in  document  MS-030-152.  Pumps  installed  as  original  equipment  are  warranted  for  1  year,  and  fall  under  the warranty supplied by the 
manufacturer,  as  outlined  in  document  MS-030-123.  This  limited  warranty  is  in  lieu  of  all  other  warranties,  expressed  or  implied (including without limitation 

implied warranties of merchantability and fitness for a particular purpose), and no other person is authorized to give any other warranty or assume obligation or 
liability  on  SHURflo's  behalf.  SHURflo  shall  not  be  liable  for  any  labor,  damage  or  other  expense,  nor  shall  SHURflo  be  liable  f or  any  indirect,  incidental  or 
consequential  damages  of  any  kind  incurred  by  the  use  or  sale  of  any  defective  Product  or  part.  This  limited  warranty  covers  Products distributed within the 
United States of America and Canada. Other world market areas should consult with the distributor for any deviation from this document. The limited warranty 

will  not  apply  to  pumps  that  were  improperly  installed,  misapplied,  or  are  incompatible  with  components  not  manufactured  by  SHURflo. Product failure due to 
foreign  debris  is  not  covered  under  the  terms  of  this  limited  warranty.  SHURflo  will  not  warrant  any  Product  that  is  physically  damaged, or altered outside 
SHURflo. Warranty  claims  may  be  resolved  by  an  authorized  dealer  service  center,  or  by  a  SHURflo  service  center.  Returns  are  to  be  shipped with charges 
pre-paid.  Package  all  returns  carefully.  SHURflo  will  not  be  responsible  for  freight  damage  incurred  during  shipping  to  a  service center. For complete Limited 

Warranty details, consult SHURflo.

911-1008 Rev D 
© 2009 SHURflo, LLC All Rights Reserved

Page 3 of 3

Visit our Web Site at http://www.shurflo.com

Shurflo reserves the right to update specifications, 
change prices, or make substitutions without notice.

 
SHURflo 

 

 

SHURflo East 

 

SHURflo Europe, Middle East, Africa 

5900 Katella Avenue 

 

52748 Park Six Court 

 

Pentair Water Belgium bvba

 

Cypress, CA 90630 

 

Elkhart, IN 46514-5427    

Industriepark Wolfstee, Toekomstlann 30 

Phone (562) 795-5200   

Phone (562) 795-5200   

B-2200 Herentals, Belgium   

Toll Free (800) 854-3218 

Toll Free (800) 854-3218 

Phone +32-14-283500 

Fax (562) 795-7564 

 

Fax (574) 264-2169 

 

Fax +32-14-283505 

FLOW TECHNOLOLIES GROUP 

5900 Katella Ave, Cypress, CA 90630  
Phone (800) 854-3218 

(562) 795-5200 

 Fax (562) 795-7564 

www.shurflo.com 

No.

Component

Part Kit

1

Upper Assembly

94-800-00

2

Valve Assembly

94-800-01

3

2.5° Drive Assembly

94-800-02

4

Motor

11-302-00

N/S

Check Valve

94-800-03

1,2,3

Pump Head

94-800-04

N/S

Pressure Switch

94-800-05

Reviews: