TYPICAL INSTALLATION

INSTALLATION AND OPERATION MANUAL

SHURflo's Pro Baitmaster pumps are designed to handle the harsh marine environment. The motor is
protected by an integral thermal breaker, and is U/L Marine listed. Baitmaster pressure switches are sealed 
and the motors are finished with Electro-coating to inhibit corrosion. A Baitmaster pump can be mounted in 
an environment where "splashed water" may be present. The Baitmaster pumps are enclosed to prevent
incidental moisture from entering; however, they 

are not submersible

. The Baitmaster delivers water on 

demand. With the output side closed (valve off) the pump will turn off. As the valve is opened the pressure 
within the output side drops. Once the pressure drops below a predetermined point the pressure 
switch closes and the pump turns on. If the output side is wide open the pump operates continuously. 
When the valve is partially opened the pump may cycle 

ON

/

OFF

 (intermittent duty) as it is able to pressurize 

faster than the water is being released.

MOUNTING

1.

Consider a dry location that allows easy access if maintenance is required. The pump should not be 
located in an area of less than one cubic foot unless adequate ventilation is provided. Excessive 
heat may trigger the integral thermal breaker and interrupt operation. When the temperature drops 
the breaker will automatically reset and the pump will start.

2.

Mount higher than the outside water (sea) level. The pump is capable of 6 ft. [1.82M] vertical prime 
above the outside water level. The pump can be mounted in any position. If mounting the pump
vertically, the pump head should be in the down position. 

+

911-738 Rev F

12/08

ECO #: 16135

Page 1 of 5