 15 V DC Connectors

Four connectors for DC power.

Rack Mount Instructions

If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be 

greater than room ambient. Keep the rack environment temperature at or below the maximum ambient temperature (Tma) 

specified by the manufacturer of the installed equipment.

Provide the proper amount of air flow inside the rack as required for safe operation of the equipment.

Do not create a hazardous condition by mounting the equipment in the rack with an uneven mechanical load.

When connecting the equipment to the supply circuit, consider the effect that overloading of the circuits might have on 

over-current protection and supply wiring. Consider all equipment nameplate ratings when addressing this concern.

Maintain reliable earthing of rack-mounted equipment. Give particular attention to indirect supply connections to the 

branch circuit (e.g., power strips).

System Installation

Installing Front-Mounted Antennas

The UA845UWB comes equipped for front-mounted antennas. Front-mounting improves RF performance of the system by 

moving the antennas to the front of the rack. When a unit is located in a rack, antennas should be either front- or remote-

mounted.

Insert the bulkhead adapters through the holes in each bracket, and secure them from each side, using the supplied 

hardware.

Connect the supplied antenna cables to the receiver antenna inputs and adapters.

Install the antennas onto the bulkhead adapters protruding through the front panel.

Note: 

For the best results, point the antennas up and away from each other at 45° angles from vertical. This ensures the best possible reception and greatly 

reduces the possibility of signal dropout. Always perform a walk-through test of the system in the performing area before using a wireless system.

Summary of Contents for UA845UWB

Page 1: ...UA845UWB Antenna Distribution System The Shure UA845UWB antenna distribution system user guide Version 2 2019 J...

Page 2: ...ount Instructions 5 System Installation 5 Connecting Receivers 6 Single Antenna Distribution Setup 6 Multiple Antenna Distribution Setup 7 Selecting the Frequency Range 8 RF Power Overload 8 Optional...

Page 3: ...he same two antennas and the cascade ports allow connection to a fifth receiver or a second UA845UWB Compatibility The UA845UWB is compatible with all Shure wireless microphone receivers operating wit...

Page 4: ...tput Connector Each amplifier has a power output connector for daisy chaining up to five Shure Diversity Single or Dual Receivers to a sin gle power source Antenna In Ports Channel A and B BNC connect...

Page 5: ...Maintain reliable earthing of rack mounted equipment Give particular attention to indirect supply connections to the branch circuit e g power strips System Installation Installing Front Mounted Anten...

Page 6: ...Amplifier Locate antennas more than 3 m 10 ft from transmitters Connecting Receivers Single Antenna Distribution Setup Using Shure low loss 50 coaxial cables connect the right and left channels 1 thro...

Page 7: ...t cables connect the power output connector of the UA845UWB to the power input connector of one receiver Connect the remaining receivers similarly Connect the power input of the unit to an AC power so...

Page 8: ...verload Antenna Indicator displays a red LED it indicates that a strong RF signal is overloading the antenna ampli fier To correct an overload condition increase the distance between the antenna and t...

Page 9: ...low loss coaxial cable such as RG 8U Shure offers pre terminated antenna cables ranging from 6 to 100 feet NOTE When ordering cables from Shure select the low loss Z models available for longer cable...

Page 10: ...s Carrier Frequency Range Band 1 174 to 216 MHz Band 2 470 to 960 MHz Band 3 1240 to 1260 MHz Band 4 1492 to 1525 MHz Band 5 1785 to 1805 MHz Distributed Output Level Gain 0 dB typical Receiver Antenn...

Page 11: ...rope compliance Authorized European representative Shure Europe GmbH Headquarters Europe Middle East Africa Department EMEA Approval Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 7262 92...

Page 12: ...er licensing and before choosing and ordering frequencies NOTE This Radio equipment is intended for use in musical professional entertainment and similar applications This Radio apparatus may be capab...