background image

 

@2015 Shure Incorporated 

 

User Manual SZ 6104 rev A.docx 

 

 

Conferencing and Discussion Systems 

SZ 6104 DCS-LAN Switcher  

USER GUIDE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SZ 6104

Page 1: ... 2015 Shure Incorporated User Manual SZ 6104 rev A docx Conferencing and Discussion Systems SZ 6104 DCS LAN Switcher USER GUIDE ...

Page 2: ...rranty 4 Your DCS 6000 Conference System 5 The DCS 6000 system 5 System components 6 Central equipment etc 6 Interpreter equipment 6 Conference units and Ch selectors 6 Accessories 6 General 7 Operating instructions 8 Local Remote selector switch 8 Local Remote Delay 9 A B and AO switches 9 Redundancy switching 10 Use of patch panel in Operators Room 11 Technical Specifications 14 System Specifica...

Page 3: ... digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inte...

Page 4: ...DIS Digital Conference System User Manual 4 Warranty The individual units in the DCS 6000 system are minimum covered by 24 months warranty against defects in materials or workmanship ...

Page 5: ...nnel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 61xx Central Unit which drives up to app 50 units with the PS CU power supply EX 6010 Extension Unit or PS 6001 DCS LAN Power Kit is available if more units are required Delayed switching on of power to the two DCS LAN...

Page 6: ...onference Unit portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F Conference Unit flush mounted with one built in channel selector Chip card and 5 voting buttons MU 6040 C D Microphone Unit for use with FD FC front plate with Loudspeaker Microphone and Buttons Avail...

Page 7: ...settings A DIP switch panel on the front can also be used to set switches and control features The unit can also be used for installations where a redundancy switching between a master and spare central unit is demanded The unit has one selector for Local Remote central unit switching and 3 on off chain switches The unit comes in a black metal box with brackets for fixing screws It can also be rac...

Page 8: ... table for these two control inputs switches Note that in case both are ON only the Local will be selected Normally an EX 6010 Extension power supply is used as the first unit after the Local Remote switch The DC power supplied to the SZ 6104 from the local or remote central unit shall supply all units connected to the two switched outputs If there is a long distance to e g the remote central unit...

Page 9: ...responding output There must be power on one of the two switched inputs To Local CU and or To Remote CU for the SZ 6104 to function These three switches are meant to be used for one A chain one B chain and connection to a remote audio output box es AO 6008 AO 6004 from the local central unit The switches can then be used to switch off the signals from the room going to a remote patch panel or room...

Page 10: ...unit is connected to REMOTE CU In case the master unit is switched off the DC power fails then the spare is selected must be powered after a short delay Pins 6 and 7 are logic outputs active low indicating power on local or remote chains In case you have 16 or less languages you only need one chain either one of the four chains of the central unit can be used but select A1 to have the fastest star...

Page 11: ...anel in a central operators room for selecting the room connections and audio output boxes for recording Note Take care that screens of all patch connectors are isolated from ground and each other as faulty ground connections may cause ground loops which again can result in corrupted data communication of the chains So use isolated patch panels where the screens are isolated from ground plate and ...

Page 12: ...at there are RP 6604 Repeaters and PS 6000 Power Supplies in the Operators Room The repeaters are needed if there are longer distances and the power supplies are needed if there are longer distances or possibility of a load of several EX 6010 s Below the same set up is shown with two rooms as Stand alone and one room as Secret ...

Page 13: ...DCS 6000 Digital Conference System User Manual 13 ...

Page 14: ... 10W maximum Power supplied from CU 61xx EX 6010 PS 6000 Temperature to guarantee specified performance 5 Deg C to 40 Deg C 35 to 80 humidity Storage temperature 20 Deg C to 60 Deg C 10 to 80 humidity Weight 0 84 kg Dimensions W x H x D 41 3 x 288 x 128 mm Connectors DCS LAN connectors 9 pieces RJ45 Control D9F sub Specifications are subject to change without notice ...

Page 15: ... BLU 5 0V BLU WHT BLU WHT 6 48V GRN GRN 7 Outgoing BRN WHT BRN WHT 8 Outgoing BRN BRN Important If other color codes are used then the four pairs are connected as follows Pair 2 Pin 1 2 Pair 3 Pin 3 6 Pair 1 Pin 4 5 Pair 4 Pin 7 8 The phase of the pairs must be correct and the wiring spec as stated in Cat5e EIA 568 B have to be followed Note Cat6 and Cat7 cables can normally only be terminated in ...

Page 16: ... 1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email info shure de Asia Pacific Shure Asia Limited 22 F 625 King s Road North Point Island East Hong Kong Phone 852 2893 4290 Fax 852 2893 4055 Email info shure com hk ...

Reviews: