Shure Incorporated
10/14
Mic Cartidge (Cardioid) [R185B]
Specifications
All measurements taken with microphone mounted on a wooden surface (76 x 76 cm)
Cartridge Type
Electret Condenser
Frequency Response
50
–
17000
Hz
Polar Pattern
MX396/C-DUAL
Cardioid (x2)
MX396/C-TRI
Cardioid (x3)
Output Impedance
170
Ω
Output Configuration
Active Balanced
Sensitivity
@ 1 kHz, open circuit voltage
−35 dBV/Pa
(18 mV)
1 Pa=94 dB SPL
Maximum SPL
1 kHz at 1% THD,
1 kΩ load
122
dB
Equivalent Output Noise
A-weighted
30
dB SPL
Signal-to-Noise Ratio
Ref. 94 dB SPL at 1 kHz
64
dB
Summary of Contents for Microflex MX396
Page 2: ...Shure Incorporated 2 14...