Unzip the zip file containing the Firmware 

Update

 Library folder and a FUU folder to the 

desktop or another convenient location on the 
PC.  

 

2. 

Connect the PC to the CCU using a LAN cable 
and switch on power. 

 

3. 

Browse to the folder 

‘MXC_Firmware_Update_Utility_xxx’ 

And open the folder 

 

4. 

Start MXC Firmware Update Utility (FUU) 
double-clicking the icon. 

 

5. 

The FUU starts. 

The FUU application will automatically find the 
folders with the firmware releases and the 
language files. 

 

 

6. 

Select to use Ethernet connection. 

Check the Ethernet settings by selecting 
‘Ethernet connection to CCU’. 

Type the CCU IP address in IP address field. 
Use IP port 3142. 

 

7. 

The FUU will now show all units in the system 
as well as information about the CCU. 

 

Summary of Contents for Microflex Complete

Page 1: ...MXC Microflex Complete Update Feature License User guide for the Shure Microflex Complete Conference System Version MXC FUU guide RevC docx...

Page 2: ...ity FUU 4 3 6 Connecting the FUU Firmware Update Utility 5 3 7 Checking the Error Status window 6 3 8 System update 7 3 9 How to update or downgrade single units 8 4 Changing of start image in MXC640...

Page 3: ...mware in all units in the system Command line button Press this Icon to get a window for sending commands to the CCU Present Units window All units present in the system are shown in this window Selec...

Page 4: ...nits but power has not been removed it is usually possible to do the update again and units that did not correctly update the first time will continue where they stopped the second time around Shure c...

Page 5: ...Utility_xxx And open the folder 4 Start MXC Firmware Update Utility FUU double clicking the icon 5 The FUU starts The FUU application will automatically find the folders with the firmware releases and...

Page 6: ...ted some errors during start up The error counter can be reset by clicking Reset error counters in CU If a counter is counting up it is a clear indication that there are communication errors IMPORTANT...

Page 7: ...Update Status window will appear and show the progress of the firmware update The update utility will update on unit type at a time so if the system consist om many different unit types the update of...

Page 8: ...ow the advanced layout Please notice that this option is only recommended for experienced users 11 Update or downgrade of one of more units of the same type can be performed by selecting the individua...

Page 9: ...Change the FUU to the Advanced FUU Layout in Setup Advanced FUU Layout Extra buttons appears in the FUU Select the MXC640 s on the unit list that needs to have a new start image uploaded by using the...

Page 10: ...selected image does not have the specified resolution an error message is shown 16 The selected image is now displayed in the MXC640 Start Image window Select Send Image to units to upload the start i...

Page 11: ...y obtaining a license the functionality can be expanded to include further functionality like More Conference Units More Interpreter Channels The file with the License key is delivered as a zipped fil...

Page 12: ...e communication errors IMPORTANT DON T DO ANY UPGRADE IF THERE ARE ERRORS IN THE COMMUNICATION If units are to be checked click the Switch to Operation Mode and then perform am AIB Automatic In bus te...

Page 13: ...est dve Display CCU Version erc Errors on CCU List errors received After the list of error counts has been printed If the command name is folowed by a the counters are reset erd Error Received In Deta...

Reviews: