background image

13 

 

Shure Incorporated 

 

 

 

When clicking ‘View/View Communication Window’ a window showing all communication to the CCU opens. 

 

 

The following list summarizes some useful commands in case communication problems with the cables occur: 

 

Command 

Description

 

aib   

Automatic In Bus Test 

avr   

Automatic Version Request 

dve   

Display CCU Version 

erc   

Errors on CCU  

List errors received. After the list of error counts 
has been printed. If the command name is folowed 
by a ‘!’ the counters are reset. 

erd   

Error Received In Detail  

Checking error received on the CCU 

eu   

Errors on Unit

 

lic   

License Info 

ou   

Overflows On Unit

 

reset   

Reset 

ru   

Reset Unit - soft/hard 

seatnames  

List Seat Names 

seats   

List Seat definitions 

sm0   

Disable monitoring 

sm1   

Normal monitoring speed  

ucc   

Display Units With Chip card 

uco   

Display Units Connected 

 

Summary of Contents for Microflex Complete

Page 1: ...MXC Microflex Complete Update Feature License User guide for the Shure Microflex Complete Conference System Version MXC FUU guide RevC docx...

Page 2: ...ity FUU 4 3 6 Connecting the FUU Firmware Update Utility 5 3 7 Checking the Error Status window 6 3 8 System update 7 3 9 How to update or downgrade single units 8 4 Changing of start image in MXC640...

Page 3: ...mware in all units in the system Command line button Press this Icon to get a window for sending commands to the CCU Present Units window All units present in the system are shown in this window Selec...

Page 4: ...nits but power has not been removed it is usually possible to do the update again and units that did not correctly update the first time will continue where they stopped the second time around Shure c...

Page 5: ...Utility_xxx And open the folder 4 Start MXC Firmware Update Utility FUU double clicking the icon 5 The FUU starts The FUU application will automatically find the folders with the firmware releases and...

Page 6: ...ted some errors during start up The error counter can be reset by clicking Reset error counters in CU If a counter is counting up it is a clear indication that there are communication errors IMPORTANT...

Page 7: ...Update Status window will appear and show the progress of the firmware update The update utility will update on unit type at a time so if the system consist om many different unit types the update of...

Page 8: ...ow the advanced layout Please notice that this option is only recommended for experienced users 11 Update or downgrade of one of more units of the same type can be performed by selecting the individua...

Page 9: ...Change the FUU to the Advanced FUU Layout in Setup Advanced FUU Layout Extra buttons appears in the FUU Select the MXC640 s on the unit list that needs to have a new start image uploaded by using the...

Page 10: ...selected image does not have the specified resolution an error message is shown 16 The selected image is now displayed in the MXC640 Start Image window Select Send Image to units to upload the start i...

Page 11: ...y obtaining a license the functionality can be expanded to include further functionality like More Conference Units More Interpreter Channels The file with the License key is delivered as a zipped fil...

Page 12: ...e communication errors IMPORTANT DON T DO ANY UPGRADE IF THERE ARE ERRORS IN THE COMMUNICATION If units are to be checked click the Switch to Operation Mode and then perform am AIB Automatic In bus te...

Page 13: ...est dve Display CCU Version erc Errors on CCU List errors received After the list of error counts has been printed If the command name is folowed by a the counters are reset erd Error Received In Deta...