background image

2

! IMPORTANT SAFETY INSTRUCTIONS !

1.

READ these instructions.

2.

KEEP these instructions.

3.

HEED all warnings.

4.

FOLLOW all instructions.

5.

DO NOT use this apparatus near water.

6.

CLEAN ONLY with dry cloth.

7.

DO NOT block any ventilation openings. Install in accordance with the manu-
facturer's instructions. 

8.

DO NOT install near any heat sources such as radiators, heat registers, stoves, 
or other apparatus (including amplifiers) that produce heat.

9.

DO NOT defeat the safety purpose of the polarized or grounding-type plug. 
A polarized plug has two blades with one wider than the other. A grounding 
type plug has two blades and a third grounding prong. The wider blade or 
the third prong are provided for your safety. If the provided plug does not fit 
into your outlet, consult an electrician for replacement of the obsolete outlet.

10.

PROTECT the power cord from being walked on or pinched, particularly at plugs, 
convenience receptacles, and the point where they exit from the apparatus.

11.

ONLY USE attachments/accessories specified by the manufacturer.

12.

13.

UNPLUG this apparatus during lightning storms or when unused for long periods of 
time.

14.

REFER all servicing to qualified service personnel. Servicing is required when the 
apparatus has been damaged in any way, such as power-supply cord or plug is dam-
aged, liquid has been spilled or objects have fallen into the apparatus, the apparatus 
has been exposed to rain or moisture, does not operate normally, or has been 
dropped.

15.

DO NOT expose the apparatus to dripping and splashing. DO NOT put objects 
filled with liquids, such as vases, on the apparatus.

USE only with a cart, stand, tripod, bracket, or table 
specified by the manufacturer, or sold with the 
apparatus. When a cart is used, use caution when 
moving the cart/apparatus combination to avoid 
injury from tip-over.

This symbol indicates that there are important operating and 
maintenance instructions in the literature accompanying this unit.

This symbol indicates that dangerous voltage constituting a risk 
of electric shock is present within this unit.

! CONSIGNES DE SÉCURITÉ IMPORTANTES !

1.

LIRE ces consignes.

2.

CONSERVER ces consignes.

3.

OBSERVER tous les avertissements.

4.

SUIVRE toutes les consignes.

5.

NE PAS utiliser cet appareil à proximité de l'eau. 

6.

NETTOYER UNIQUEMENT avec un chiffon sec.

7.

NE PAS obstruer les ouvertures de ventilation. Installer en respectant les con-
signes du fabricant.

8.

Ne pas installer à proximité d'une source de chaleur telle qu'un radiateur, une 
bouche de chaleur, un poêle ou d'autres appareils (dont les amplificateurs) pro-
duisant de la chaleur.

9.

NE PAS détériorer la sécurité de la fiche polarisée ou de la fiche de terre. Une 
fiche polarisée comporte deux lames dont l'une est plus large que l'autre. Une 
fiche de terre comporte deux lames et une troisième broche de mise à la terre. 
La lame la plus large ou la troisième broche assure la sécurité de l'utilisateur. Si 
la fiche fournie ne s'adapte pas à la prise électrique, demander à un électricien 
de remplacer la prise hors normes. 

10.

PROTÉGER le cordon d'alimentation afin que personne ne marche dessus et que 
rien ne le pince, en particulier au niveau des fiches, des prises de courant et du point 
de sortie de l'appareil.

11.

UTILISER UNIQUEMENT les accessoires spécifiés par le fabricant.

12.

13.

DÉBRANCHER l'appareil pendant les orages ou quand il ne sera pas utilisé pendant 
longtemps.

14.

CONFIER toute réparation à du personnel qualifié. Des réparations sont nécessaires 
si l'appareil est endommagé de quelque façon que ce soit, comme par exemple : cor-
don ou prise d'alimentation endommagé, liquide renversé ou objet tombé à l'intérieur 
de l'appareil, exposition de l'appareil à la pluie ou à l'humidité, appareil qui ne marche 
pas normalement ou que l'on a fait tomber.

15.

NE PAS exposer cet appareil aux égouttures et aux éclaboussements. NE PAS poser 
des objets contenant de l'eau, comme des vases, sur l'appareil.

UTILISER uniquement avec un chariot, un pied, un trépied, 

un support ou une table spécifié par le fabricant ou vendu 

avec l'appareil. Si un chariot est utilisé, déplacer l'ensemble 

chariot-appareil avec précaution afin de ne pas le renverser, 

ce qui pourrait entraîner des blessures.

Ce symbole indique que la documentation fournie avec 
l'appareil contient des instructions d'utilisation et d'entretien 
importantes.

Ce symbole indique la présence d'une tension dangereuse 
dans l'appareil constituant un risque de choc électrique.

! WICHTIGE SICHERHEITSHINWEISE !

1.

Diese Hinweise LESEN.

2.

Diese Hinweise AUFHEBEN.

3.

Alle Warnhinweise BEACHTEN.

4.

Alle Anweisungen BEFOLGEN.

5.

Dieses Gerät NICHT in der Nähe von Wasser verwenden. 

6.

NUR mit einem sauberen Tuch REINIGEN.

7.

KEINE Lüftungsöffnungen verdecken. Gemäß den Anweisungen des Herstell-
ers einbauen.

8.

Nicht in der Nähe von Wärmequellen, wie Heizkörpern, Raumheizungen, 
Herden oder anderen Geräten (einschließlich Verstärkern) installieren, die 
Wärme erzeugen.

9.

Die Schutzfunktion des Schukosteckers NICHT umgehen. Bei Steckern für die 
USA gibt es polarisierte Stecker, bei denen ein Leiter breiter als der andere ist; 
US-Stecker mit Erdung verfügen über einen dritten Schutzleiter. Bei diesen 
Steckerausführungen dient der breitere Leiter bzw. der Schutzleiter Ihrer 
Sicherheit. Wenn der mitgelieferte Stecker nicht in die Steckdose passt, einen 
Elektriker mit dem Austauschen der veralteten Steckdose beauftragen. 

10.

VERHINDERN, dass das Netzkabel gequetscht oder darauf getreten wird, ins-
besondere im Bereich der Stecker, Netzsteckdosen und an der Austrittsstelle 
vom Gerät.

11.

NUR das vom Hersteller angegebene Zubehör und entsprechende Zusatzgeräte ver-
wenden.

12.

13.

Das Netzkabel dieses Geräts während Gewittern oder bei längeren Stillstandszeiten 
aus der Steckdose ABZIEHEN.

14.

Alle Reparatur- und Wartungsarbeiten von qualifiziertem Kundendienstpersonal 
DURCHFÜHREN LASSEN. Kundendienst ist erforderlich, wenn das Gerät auf 
irgendwelche Weise beschädigt wurde, z.B. wenn das Netzkabel oder der 
Netzstecker beschädigt wurden, wenn Flüssigkeiten in das Gerät verschüttet wurden 
oder Fremdkörper hineinfielen, wenn das Gerät Regen oder Feuchtigkeit ausgesetzt 
war, nicht normal funktioniert oder fallen gelassen wurde.

15.

Dieses Gerät vor Tropf- und Spritzwasser SCHÜTZEN. KEINE mit Wasser gefüllten 
Gegenstände wie zum Beispiel Vasen auf das Gerät STELLEN.

NUR in Verbindung mit einem vom Hersteller angegebenen 
oder mit dem Gerät verkauften Transportwagen, Stand, Stativ, 
Träger oder Tisch verwenden. Wenn ein Transportwagen ver-
wendet wird, beim Verschieben der Transportwagen-Geräte-
Einheit vorsichtig vorgehen, um Verletzungen durch Umkippen 

Dieses Symbol zeigt an, dass gefährliche Spannungswerte, 
die ein Stromschlagrisiko darstellen, innerhalb dieses Geräts 
auftreten.

Dieses Symbol zeigt an, dass das diesem Gerät beiliegende 
Handbuch wichtige Betriebs- und Wartungsanweisungen ent-
hält.

Summary of Contents for AMS8100

Page 1: ...ATIC MICROPHONE MIXER NOTE Shure AMS8100 Mixers are designed for use only with Shure AMS Condenser Microphones Conventional condenser or other microphones will not operate properly with the AMS8100 OUTPUT 2 4 6 8 0 1 2 3 4 5 6 7 8 AUX MASTER PHONES POWER LIMITER 30 12 0 12 0 AMS8100 ...

Page 2: ...ndant les orages ou quand il ne sera pas utilisé pendant longtemps 14 CONFIER toute réparation à du personnel qualifié Des réparations sont nécessaires si l appareil est endommagé de quelque façon que ce soit comme par exemple cor don ou prise d alimentation endommagé liquide renversé ou objet tombé à l intérieur de l appareil exposition de l appareil à la pluie ou à l humidité appareil qui ne mar...

Page 3: ...iones importantes de funcionamiento y mantenimiento ISTRUZIONI IMPORTANTI PER LA SICUREZZA 1 EGGETE queste istruzioni 2 CONSERVATE queste istruzioni 3 OSSERVATE tutte le avvertenze 4 SEGUITE tutte le istruzioni 5 NON usate questo apparecchio vicino all acqua 6 PULITE l apparecchio SOLO con un panno asciutto 7 NON ostruite alcuna apertura per l aria di raffreddamento Installate l apparec chio segue...

Page 4: ...tions as large as 400 input channels The AMS8100 is fully link compatible with Shure s SCM810 and FP410 automatic mixers Thesingle rack heightchassisisidealforinstallations with limited rack space The removable header type input and output connectors are quick convenient and eliminate the time and expense of wiring XLR microphone connectors TheAMS8100isdesignedfor100 120Vac operationand its line c...

Page 5: ...English CONTENTS Description 5 Features 5 Contents 6 Operating Principles 7 Front Panel 8 Rear Panel 9 AMS Microphones 10 Dip Switches 11 Setup 12 Mixer Linking 14 Specifications 16 Advanced Functions 17 ...

Page 6: ...ones are activated In a sound reinforcement application if the system gain is set below the feedback point with a single microphone gated on the increase in system gain with addi tional on microphones could cause feedback NOMA pre vents this by automatically reducing all on microphone gains by 3 dB as additional microphones are gated on This main tains constant total system gain avoiding feedback ...

Page 7: ...egion for compensation of off axis micro phones or for cutting the high frequency sibilance of mi crophones Î AUX Level Control Sets the input level for aux level equipment connected to the adjacent 1 4 inch phone jack INPUT or rear panel 1 4 inch AUX input Ï Aux INPUT 1 4 inch Phone Jack Mixes external auxilia ry or line level sources i e tape recorders into output This input is not automatic Sig...

Page 8: ...anced output signal for connection to amplifiers record ers or other mixers Pin 1 hot Pin 2 cold Pin 3 ground Ifconnecting to an unbalancedinput connectpin 2 to pin 3 ground Ï OUTPUT LEVEL Switch Switches between 4 dBu line 10 dBV aux and mic level output Switch is lo cated behind OUTPUT connector Ð DIRECT OUT 1 4 inch Phone Jacks Provides non gated aux level signal from each channel Direct outs a...

Page 9: ...tyle microphone which has an XLRbuiltin and a cable as shown below mustbeused tocon nect it to the AMS8100 This same type of cable can be used as an extension cable between the AMS22 or AMS28 micro phones and the AMS8100 mixer Under most circumstances lengths of 150 meters 500 ft or greater of high quality 2 conductor shielded microphone cable can be used between the microphone and the AMS mix er ...

Page 10: ...S8100functions asa standard 8x1 mixer Last Mic Lock On Last Mic Lock On feature keeps the mostrecently activated microphone turned on until a newlyac tivated microphone takes its place When defeated micro phones turn off after their preset hold time Hold Time Adjusts the time an activated microphone which is not locked on remains on after the talker stops talk ing Settings are 0 4 seconds or 1 0 s...

Page 11: ...lifiers or recorders 3 If additional AMS8100 mixers are to be linked to increase the number of microphone inputs connect them by means ofthe Link In and Link Outjacks Connectthe LINK OUT of the first mixer to the LINK IN of the next mixer and so on Leave the LINK IN jack of the first mixer and the LINK OUT jack of the last mixer unconnected NOTE These jacks are forlinking only notfor audio inputs ...

Page 12: ... FULL CCW 50 ROTATION HIGH FREQUENCY SHELVING EFFECTS 200 10 8 6 4 2 0 2 4 6 8 10 1 000 10 000 20 000 FREQUENCY Hz FULL CW FULL CCW 50 ROTATION LIMITER The AMS8100 has a peak output limiter that prevents dis tortion during loud program peaks without affecting normal program levels Increasing the individual or Master level con trols will increase the average output and in turn the amount of limitin...

Page 13: ...ix mix er will function with the microphones connected to it Linking an AMS8100 to AMS8000 AMS4000 To link the AMS8100 with AMS8000 or AMS4000 mixers a special cable must be constructed by the installer see be low Use high quality 2 conductor shielded cable Itisimpor tantto connectthe mini DINconnectorto the AMS8100 sLINK IN and the 1 4 in connectors to the AMS8000 or AMS4000 LINK OUT connector Wh...

Page 14: ...nctions such as Last Mic Lock on and MaxBus are connected on all linked mixers and are not affected by the Global Local switch An example of the possibilities of this setup is shown in Figure 8 Here two AMS8100s are set to Local and the result ing sound distribution provides local sound reinforcement while avoiding feedback This is a simple mix minus setup The third AMS8100 is set to Global and fe...

Page 15: ...able to 1 0 s Decay Time 0 5 s Off Attenuation 15 dB switchable to Overload and Shorting Protection Shorting outputs even for prolonged periods causes no dam age Microphone inputs are not damaged by signals up to 3 V Line and Monitor inputs by signals up to 20 V Equalization Low frequency 6 dB octave cut adjustable corner from 50 to 300 Hz High frequency 6 dB at 5 kHz 8 dB at 10 kHz shelving Limit...

Page 16: ...losure to logic ground forces channel on see illustra tion B above Factory setting provides that when both Mute and Override are activated Mute takesprecedence seeInter nal Modifications for Override precedence LOGIC GROUND Logic ground is distinct from the AMS8100 audio ground Make all logic ground connections to thispin includingpowersupplygroundofexternal logiccircuit ry To avoid switching clic...

Page 17: ...ough sneeze etc all other microphones will be muted CHAIRPERSON CONTROLLED MUTING CH 1 M3 M5 M5 M7 M2 M4 M6 LOGIC GROUND Remote Channel On Indicators Remote indicators can be used to indicate when a talker s microphone is on Connect the LEDs and a 5 volt supply to the GATE OUT pins as shown in the illustration REMOTE CHAN NEL ON INDICATORS Channels 1 2 and 3 shown modified To avoid switching click...

Page 18: ...24 volt relays can be used with the AMS8100 without modification if the relay coil current draw is under 500 mA LOUDSPEAKER MUTING 12 V POWER SUPPLY G5 G3 G1 LOGIC GROUND D 1N4148 FROM POWER AMP D D D Filibuster Mode In normal operation when several people talk each mi crophone gates on so that no speech is missed In filibuster action a microphone that is gated on prevents other micro phones from ...

Page 19: ...o power transformer T901 and using a screwdriver turn the center rotor to the 230 V position 4 Locate Fuse F901 and remove it Replace it with a 100 mA 250 V time delay fuse for 220 240 volt operation 200 mA 250 V slow blow fuse for 100 120 volt operation Fuse part numbers are Fuse Type Shure Part No Littelfuse Part No 100 mA 250 V 80C258 218 100 200 mA 250 V 80BC8196 239 200 5 Replace the power co...

Page 20: ... to be used for the desired gain Master Section Gain Resistance 6 dB 5 1 kW 0 10 kW 6 dB 20 kW Procedure Remove resistor R9230 Install new resistor at jumper X914 Limiter Threshold All three threshold settings 16 8 and 4 dBu can be changed To shift the threshold down by 6 dB 10 2 and 2 dBu resistor R will be 82 kW To shift the limiter thresholds up by 6 dB 22 14 10 dBu R will be 330 kW Procedure R...

Page 21: ...t rec ommended Procedure Install a 2 MW resistor at jumpers X903 Remote Control of Link Global Local Off Attenua tion Last Mic Lock on and Automatic Manual DIP Switches If desired these functions can each be remotely con trolled with an SPST switch Procedure 1 Solder a wire in the pc board jumper hole adjacent to the desired function printed on the pc board These jumpers are located just behind DI...

Page 22: ...s http www shure com 5800 W Touhy Avenue Niles IL 60714 4608 U S A Phone 800 257 4873 Fax 847 866 2279 In Europe Phone 49 7131 72140 Fax 49 7131 721414 In Asia Phone 852 2893 4290 Fax 852 2893 4055 Elsewhere Phone 847 866 2200 Fax 847 866 2585 ...

Reviews: