P/N 1128479 Rev. A

7

Trickle Charger Installation

STEP 1:

  Plug extension cable 

9

 into trickle charger 

8

. Make 

sure red wire with female bullet connector is con

-

nected to male pin on trickle charge connector.

STEP 2:

  Route extension cable from weatherproof 120-volt 

outlet to control box. Extension cable can be routed 

underground or along fenceline. Routing extension 

cable through conduit is recommended.

STEP 3:

  Remove extra pair of bullet connections from cable 

exiting bottom of control box 

1

.

STEP 4:

    If desired, extension cable can be cut shorter at con

-

trol box to remove excess wire. If extension cable is 

shortened, crimp male bullet connector to red wire 

and crimp female bullet connector to black wire of 

extension cable.  Leave enough slack for bullet con

-

nector ends to be inside control box. Make sure trickle 

charger is not plugged in before cutting extension 

cable.

STEP 5:

  Connect extension cable 

9

 to control box 

1

. Red 

wire from extension cable connects to white wire from 

control box.

NOTE:

 Extension cable is rated for direct burial.

NOTE:

 Check local building codes for requirements.

STEP 6:

  Measure battery voltage. A fully charged battery 

should read about 12.7 volts. Prior to charging, typi

-

cal battery voltage may read between 12.2 and 12.7 

volts.

STEP 8:

  Measure battery voltage again. Battery voltage should 

read 12.8 to 14.5 volts while trickle charger is charg

-

ing.

STEP 7:

  Plug trickle charger into 120-volt outlet.

9

1

8

9

1

BATTERY VOLTAGE AND TRICKLE CHARGING

black

 

wire

 

w

/

male

 

bullet

 

connector

important

connect

 

correct

 

side

 

of

 

extension

 

cable

 

to

 

trickle

 

charger

do

 

not

 

plug

 

trickle

 

charger

 

in

 

yet

route

 

extension

 

wire

 

through

 

conduit

red

 

wire

 

w

/

female

 

bullet

 

connector

red

 

wire

white

 

wire

black

 

wires

Summary of Contents for AutoGate

Page 1: ...P N 1128479 Rev A AutoGate Electric Farm Swing Gate Trickle Charge Version ...

Page 2: ...ement products from our factory to the owner will be paid by us If the product returned is found in our judgement to be non warrantable the owner will be contacted to authorize repair work purchase of a replacement product or return of the product all of which will be at the owner s expense Payment authorization must be received by us before any non warrantable product is repaired replaced or retu...

Page 3: ...IME Mounting Hardware 1 System Components 2 Stop Plate and Brackets Installation 3 4 Control Box Installation 5 Actuator Installation 6 Trickle Charger Installation 7 Final Adjustments 8 Replacement Parts 9 We at Shur Co are concerned with your safety and the safety of all those operating this system Therefore we have provided safety de cals at various locations on your system Keep decals as clean...

Page 4: ...072 Hex Head Cap Screw M10 x 1 1 2 1705361 Nylock Hex Nut M10 1700407 Hex Nut 3 8 1700400 Hex Head Self Drilling Screw 3 8 x 1 1704931 Nylock Hex Nut Flange 5 16 1706065 Hex Head Lag Screw 3 8 x 1 1 2 1700428 Flat Washer 5 16 1706066 Hex Head Lag Screw 3 8 x 2 1 2 1700429 Flat Washer 5 16 1706073 Carriage Bolt 3 8 x 7 1703231 Cable Tie 8 1700434 Lock Washer 3 8 1704427 Wire Lock Pin 3 8 x 1 3 4 Q ...

Page 5: ...9 is long enough to connect trickle charger to control box Routing extension through conduit is recommended Use a weatherproof outlet cover or box to protect trickle charger If livestock can come into contact with gate when fully open or closed gate should be positioned near a sturdy post or fence to prevent damage to bracketry A stop bracket 6 and stop plate 7 are included for closed position if ...

Page 6: ...g 3 8 carriage bolts F drill 3 8 holes through post If using 3 8 lag screws drill 1 4 holes into post at least 2 1 2 deep E STOP PLATE GATE BRACKET HINGE BRACKET STEP 5 Select appropriately sized U bolts Q R or S for gate crossbar Install gate bracket 5 and 5 16 nuts L but do not tighten nuts at this time Bracket should be able to slide on crossbar STEP 6 Placeinnerslidehingebracket 3 intooutersli...

Page 7: ... to allow actuator to pivot on hinge bracket Do not place nut at this time Push gate fully open Swing actuator towards gate until actuator points towards gate bracket 5 If actuator body makes contact with gate adjust inner slide hinge bracket 3 out farther by one hole location Alternatively if there is adequate clearance between actuator and gate inner slide hinge bracket may be brought closer to ...

Page 8: ...r installation STEP 1 Mount control box 1 above hinge bracket Drill holes and install fasteners For wooden posts 3 8 lag screws can be used For metal posts use 3 8 self tapping screws STEP 2 Loosen four 10 fasteners on side holding front panel with 5 16 nut driver Remove front panel STEP 3 Loosentwo 10fastenersonbottomofcontrolboxand remove bottom cover for access to cable connectors Gently pull o...

Page 9: ... line up with actuator mounting hole Install actuator 4 using cap screws B nylock nuts J and wire lock pin T Tighten nut until snug then back off 1 4 turn STEP 4 Tighten U bolt nuts to secure gate bracket If U bolts cannot be used drill 5 16 holes into gate and fasten gate bracket using 3 8 self tapping screws C u bolt 4 1 4 5 5 4 B J L T C NOTE U bolts may not have enough holding power on some th...

Page 10: ...n nector ends to be inside control box Make sure trickle charger is not plugged in before cutting extension cable STEP 5 Connect extension cable 9 to control box 1 Red wire from extension cable connects to white wire from control box NOTE Extension cable is rated for direct burial NOTE Check local building codes for requirements STEP 6 Measure battery voltage A fully charged battery should read ab...

Page 11: ...ear hinge point to allow for gate to open while preventing cable from being pinched by hinge bracket Open and close gate to verify actuator cable has adequate slack and does not become pinched STEP 3 Secure and finalize wiring from trickle charger to control box STEP 4 Gently push connectors and excess wire up into con trol box channel If needed top panel can be removed for better access to wire c...

Page 12: ... 1 2 15 1127905 Hinge Post Fixed Bracket 16 1700429 Flat Washer 3 8 17 1700434 Lock Washer 3 8 18 1700407 Hex Nut 3 8 Item Part Description 19 1706073 Carriage Bolt 3 8 x 7 For Metal Posts 20 1127908 Hinge Post Slide Bracket 21 1704416 Cap Screw 5 16 x 1 22 1700428 Flat Washer 5 16 23 1700419 Hex Nut 5 16 24 1127655 Linear Actuator 25 1706072 Cap Screw M10 x 35mm 26 1705361 Hex Nut M10 27 1704427 ...

Page 13: ...P N 1128479 Rev A Notes 10 ...

Page 14: ...P N 1128479 Rev A Notes 11 ...

Page 15: ...P N 1128479 Rev A Notes 12 ...

Page 16: ......

Reviews:

Related manuals for AutoGate