Remark:
1.
C
10
means 10 hour rate capacity, generally it is the same with rated capacity, for example,
for 2V300Ah battery, its rated capacity C
10
300, for 12V100Ah battery, its capacity C
10
100;
2.
Usually there is only 1 cell in 2V monobloc and 6 cells in 12V monobloc;
3.
The total charging voltage must be less than the maximum voltage of the charger, if there
are many batteries, please charge time after time;
4.
Current limited means maximum current during the process of charging, 0.05C
10
means
0.05 times rated capacity. For example, the current limited of 2V300Ah battery is 0.05 ×
300 15A;
5.
The precision of current during charge and discharge should be less than 1%;
6.
Especially: for battery, storage should be not more than 6 months, because it is harmful to
battery capacity and life, though the capacity can be partly renewed, service life cannot be
renewed, this will affect the performance of warranty. Therefore, the battery should be
used within 6 months after delivery as best as you can.
4 Charging Equipment and Tools
No
Tool
Explanation
Purpose
1
Battery
Test
Equipment
or
Power System
If there is no Battery Test
Equipment, we can use
Power System instead of it.
Used to recharge and
test batteries
2
multimeter
Precision: 5mV
Test battery voltage
3
ampere meter
Precision: less than 3%
Test
charge
and
discharge current
4
monkey spanner
Tightening the screws
5
screwdriver
Prize up battery top
cover
5 Attention Proceedings
1. Use battery testing equipment to recharge batteries, if there is not, the power system
can be used. Pay attention to the parameter of charge and discharge.
2. In order to prevent exceptional condition, person specially assigned for battery