Showven SPARKULAR miniFALL BT14 User Manual Download Page 6

Page-5/6

Please don’t set the same DMX address when controlling with host controller ZK6200/ZK6300. 
Host controller can reduce the performance risk by monitor the working status of each machine.

Options

Range

500-620

ON/OFF

70-100

Factory Mode/

User Mode

2 DMX Channel/

4 DMX Channel

Explanation

Set Temperature

Setup inner Core temperature. Please don't change default

value without engineer's suggestion from SHOWVEN.

Auto Heat

Auto preheat function switch after turning on

machine

Density

Adjust the sparks density. Please don't change default

value without engineer's suggestion from SHOWVEN.

Mode Selection

Factory Mode is factory debugging mode, User 

Mode is using mode

DMX Channel

Mode

2 DMX Channel is standard mode, 4 DMX Channel

is speical mode.

On/Off

Standby Switch

When it’s on, the machine can only generate spark

when pre-heating finish.

Default Parameter

Press “ENTER” to restore all parameters to the

factory settings.

Cable DMX mode

When using the DMX controller, the system takes 2 channels

The First channel

Functions

0-15

Fountain OFF

16-255

Fountain ON

The second channel

Functions

60-80

Clear Material

20-40

Emergency Stop 

0-10

240-255

Pre-heat OFF

Disable in Auto-heat

Pre-heat ON

Disable in Auto-heat

Summary of Contents for SPARKULAR miniFALL BT14

Page 1: ...User Manual SPARKULAR miniFALL V1 0 ...

Page 2: ... only use sands to extinguish Composite Ti should keep away from moisture and stored in a dry sealed environment Keep audience and flammable material at a minimum distance of 1m from SPARKULAR miniFALL and the sparks it generated Make sure sparks shoot out from Sparkular miniFALL can NOT touch any objects After the show please stop preheating or powering off and move the SPARKULAR miniFALL only af...

Page 3: ...iFALL Model No BT14 Parameter Size Hopper capacity Material Consumption Weight Input Working Power Working Temperature Casing Fall Length Interface Double DMX input interfaces double AC power interfaces 3 4m large 2 3m medium 280g 15g min 3kg 220 240VAC 50 60Hz 130w 10 50 Anti flame ABS 150 160 240mm ...

Page 4: ...eating signal light turns on MENU Short press to switch interface press for 3 seconds can switch to the advanced setup interface Parameters down Parameters up ENTER Confirm and save parameters Quick Flashing Preheating Long on Finish preheating and ready to work Slow Flashing Error warning Composite Ti with RFID card swiping cards used to identify parameters and types of granules Please note that ...

Page 5: ...U key to enter different options wait 3 seconds to return to the main interface Options Set DMX Address Wireless Control Manual Fountain Range 1 512 ON OFF ON OFF Instructions Set the DMX address Wireless function switch you can match codeWhen shows ON Manual fountain switch for testing purposes only Error Informations Explanation E0 System IC System error E2 Temp Sensor Temperature sensor was dam...

Page 6: ... density Please don t change default value without engineer s suggestion from SHOWVEN Mode Selection Factory Mode is factory debugging mode User Mode is using mode DMX Channel Mode 2 DMX Channel is standard mode 4 DMX Channel is speical mode On Off Standby Switch When it s on the machine can only generate spark when pre heating finish Default Parameter Press ENTER to restore all parameters to the ...

Page 7: ...rs in warranty period Please don t repair machine without factory permission 1 Damage caused by improper transportation using management and maintenance or damage caused by human factors 2 Disassemble modified or maintenance products without Showven s permission 3 Damage caused by external reasons lightning strike power supply etc 4 Damage caused by improper installation or use For product damage ...

Page 8: ...n Technologies Co Ltd Add Building B1 Changsha E center No 18 Xiangtai Road Economic Technology Development Zone Hunan China Tel 86 731 83833068 Fax 86 731 83833069 Web www showven com E mail info showven com ...

Reviews: