Showven SPARKULAR miniFALL BT14 User Manual Download Page 4

Page-3/6

Light emitting diode display area:

Bottom Indication Light

READY

After turning on machine, it will automatically preheat around 6 minutes, when the 

"READY" green light turns from flashing into long on, indicates that the machine is ready to work. 
When it flashes slowly, it indicates some error.
DMX

Flashing shows that DMX signal is connected, otherwise is without signal

FAULT

When any malfunction , the light turns on

HEAT

When the machine is heating, signal light turns on

MENU

Short press to switch interface, press for 3 seconds can switch to the advanced setup 

interface.
-

Parameters down

+

Parameters up

ENTER

Confirm and save parameters.

Quick Flashing

Preheating

Long on

Finish preheating and ready to work

Slow Flashing

Error warning

Composite  Ti  with  RFID  card,  swiping  cards  used  to  identify                                        
parameters and types of granules.
Please note that granules RFID card can increase the single 
machine specific working time. The card is disposable, can only use 
once.

Radio frequency identification area:

Operation Panel:

LCD information display area, showing operate menu and working status of machine.

Summary of Contents for SPARKULAR miniFALL BT14

Page 1: ...User Manual SPARKULAR miniFALL V1 0 ...

Page 2: ... only use sands to extinguish Composite Ti should keep away from moisture and stored in a dry sealed environment Keep audience and flammable material at a minimum distance of 1m from SPARKULAR miniFALL and the sparks it generated Make sure sparks shoot out from Sparkular miniFALL can NOT touch any objects After the show please stop preheating or powering off and move the SPARKULAR miniFALL only af...

Page 3: ...iFALL Model No BT14 Parameter Size Hopper capacity Material Consumption Weight Input Working Power Working Temperature Casing Fall Length Interface Double DMX input interfaces double AC power interfaces 3 4m large 2 3m medium 280g 15g min 3kg 220 240VAC 50 60Hz 130w 10 50 Anti flame ABS 150 160 240mm ...

Page 4: ...eating signal light turns on MENU Short press to switch interface press for 3 seconds can switch to the advanced setup interface Parameters down Parameters up ENTER Confirm and save parameters Quick Flashing Preheating Long on Finish preheating and ready to work Slow Flashing Error warning Composite Ti with RFID card swiping cards used to identify parameters and types of granules Please note that ...

Page 5: ...U key to enter different options wait 3 seconds to return to the main interface Options Set DMX Address Wireless Control Manual Fountain Range 1 512 ON OFF ON OFF Instructions Set the DMX address Wireless function switch you can match codeWhen shows ON Manual fountain switch for testing purposes only Error Informations Explanation E0 System IC System error E2 Temp Sensor Temperature sensor was dam...

Page 6: ... density Please don t change default value without engineer s suggestion from SHOWVEN Mode Selection Factory Mode is factory debugging mode User Mode is using mode DMX Channel Mode 2 DMX Channel is standard mode 4 DMX Channel is speical mode On Off Standby Switch When it s on the machine can only generate spark when pre heating finish Default Parameter Press ENTER to restore all parameters to the ...

Page 7: ...rs in warranty period Please don t repair machine without factory permission 1 Damage caused by improper transportation using management and maintenance or damage caused by human factors 2 Disassemble modified or maintenance products without Showven s permission 3 Damage caused by external reasons lightning strike power supply etc 4 Damage caused by improper installation or use For product damage ...

Page 8: ...n Technologies Co Ltd Add Building B1 Changsha E center No 18 Xiangtai Road Economic Technology Development Zone Hunan China Tel 86 731 83833068 Fax 86 731 83833069 Web www showven com E mail info showven com ...