Operation Panel
1. Control button area
MENU: switch through setup menu
+: Parameter up; multiplex “TIMER” (smoke output time)
-: Parameters down; multiplex “VOLUME” (smoke output start)
ENTER: confirm and save parameters (screen will blink once when save successfully); multiplex
“STOP”.
NOTE: Screen will switch to main interface automatically if not press any button in long time.
▲
Interface
1. Main interface:
First Line: DMX address, “:” blinks when there is DMX in signal.
Second Line: shows machine core temperature and pressure. The machine ready for operate
only when both temperature and pressure value close to 100%.
2. Error information:
Example of “TIMER” setting function in the menu:
1. “set interval 10s”
2. “set duration 2s”
SONICBOOM will repeat: firing 2s, interval of 10s, firing 2s, interval 10s…
Press “VOLUME” button under main interface, SONICBOOM activated and start to generate
smoke, and press “STOP” to stop the machine.
Error information
Explanation
E0 System IC
Circuit fault
E1 Pressure
Pressure faults, no fog fluid or pump error
E2 K temp. Sensor
Temperature sensor fault
E3 Evacuate
Evacuate fuel pipe fault
E5 Temp Over
Circuit fault
E6 Heat Fail
Heating element damage or circuit fault