Showven SONICBOOM PLUS SMOKEJET User Manual Download Page 5

 

 

Channel 11 

LED dimmer, (0-9) OFF, (10-255) LED brightness increase 

 

3. 14 channels mode: 

Channels 

Function 

Channel 1 

Firing: (0-9) OFF, ( 10-255) ON 

Channel 2 

Inner LED RED: (0-9) OFF, (10-255) LED brightness increase 

Channel 3 

Inner LED GREEN: (0-9) OFF, (10-255) LED brightness increase 

Channel 4 

Inner LED BLUE: (0-9) OFF, ( 10-255) LED brightness increase 

Channel 5 

Inner LED AMBER: (0-9) OFF, ( 10-255) LED brightness increase 

Channel 6 

Outer LED RED: (0-9) OFF, (10-255) LED brightness increase 

Channel 7 

Outer LED GREEN, (0-9) OFF, (10-2551) LED brightness increase 

Channel 8 

Outer LED BLUE, (0-9) OFF, (10-255) LED brightness increase 

Channel 9 

Outer LED AMBER, (0-9) OFF, (10-255) LED brightness increase 

Channel 10 

LED Random: (0-9) OFF, (10-255) LED random color 

Channel 11 

LED Random (inner LED change color): (0-9) OFF, (10-255) LED random 

color 

Channel 12 

LED color change speed: (0-9) OFF, (10-255) LED color change speed 

increase  

Channel 13 

LED strobe: (0-9) OFF, (10-255) LED strobe increase 

Channel 14 

LED dimmer, (0-9) OFF, (10-255) LED brightness increase 

NOTE: Manual function disabled when DMX connected. 
 

E1 Pressure error explanation 

In  order  to  protect  pump,  SONICBOOM  will  running  self  check  program  to  find  out  whether 
there are fog fluid in the fuel pipe. 
1. E1 pressure error activation 
When there is no fog fluid in the fuel tank, system can not reach preset pressure even turn on 
for a long time. The pump will stop working, and report E1.  
2. Way to clear E1 error 

 Fill the fog fluid tank, then restart the machine.  
 Press 

VOLUME

 to reset.  

 DMX Channel 1, start a firing.  

 

 Maintenance 

1. Use SHOWVEN original fog fluid for the best effect of SONICBOOM. Warranty will be void if 
any other type fluid is used. 
2.  Don

t  disassemble  the  machine  by  unauthorized  person,  modifications  to  the  machine  are 

not allowed. 
3.  Excessive  dust, liquid  or  dirt etc  on  the  equipment  will  affect  performance  of the  machine 
and cause poor heat dissipation. Remove dust with air compressor, vacuum or soft brush. Use a 
damp cloth to clean the case.   
4. Before storing the machine, run distilled water through the system to help avoid condensing 
the pump or heater. 

Summary of Contents for SONICBOOM PLUS SMOKEJET

Page 1: ...USER MANUAL SONICBOOM PLUS SMOKEJET V2 0 2021 04 23 Showven Technologies Co Ltd ...

Page 2: ... power connection etc carefully if can t solve the problem please contact SHOWVEN or your local SHOWVEN partner for advise Suggest use SHOWVEN original FX S fog fluid other fluid may lead to clog or malfunction Please do not adding any other material such as pigment water etc to the fuel bottle To avoid fluid spill make sure fog fluid not exceed related MAXIMUM fluid level line When install SONICB...

Page 3: ...irst Line DMX address blinks when there is DMX in signal Second Line shows machine core temperature and pressure The machine ready for operate only when both temperature and pressure value close to 100 2 Error information Example of TIMER setting function in the menu 1 set interval 10s 2 set duration 2s SONICBOOM will repeat firing 2s interval of 10s firing 2s interval 10s Press VOLUME button unde...

Page 4: ...ED brightness increase Channel 6 Outer LED GREEN 0 9 OFF 10 2551 LED brightness increase Channel 7 Outer LED BLUE 0 9 OFF 10 255 LED brightness increase Channel 8 LED Random 0 9 OFF 10 255 LED random color use together with channel 9 Channel 9 LED color change speed 0 9 OFF 10 255 LED color change speed increase Channel 10 LED strobe 0 9 OFF 10 255 LED strobe increase Options Range Explanation DMX...

Page 5: ...nnel 14 LED dimmer 0 9 OFF 10 255 LED brightness increase NOTE Manual function disabled when DMX connected E1 Pressure error explanation In order to protect pump SONICBOOM will running self check program to find out whether there are fog fluid in the fuel pipe 1 E1 pressure error activation When there is no fog fluid in the fuel tank system can not reach preset pressure even turn on for a long tim...

Page 6: ...f the fog fluid in the heating pipe Possible Reason 1 Use other type of low quality fog fluid instead of SHOWVEN original fog fluid Possible reason 2 Use inappropriate fog fluid For different types of fog fluid the atomization temperature is different B Heating aluminum pipe clog early symptom for heating aluminum pipe clog is fog fluid spill caused by insufficient atomization Use other brand flui...

Page 7: ...thout factory permission Below situations NOT included in warranty service 1 Damage caused by improper transportation usage management and maintenance or damage caused by human factors 2 Disassemble modify or repair products without permission 3 Damage caused by external reasons lightning strike power supply etc 4 Damage caused by improper installation or use For product damage not included in war...

Page 8: ...Showven Technologies Co Ltd Tel 86 731 83833068 Web www showven cn E mail info showven cn Add Liuyang Economic Development Zone Changsha 410300 Hunan Province P R China ...