14
SHOWTEX INSTALLATION MANUAL
RAIL H100 ROPE CONTROLLED
Total track length (m)
A
B
L
HOW TO
DETERMINE NUMBER OF ATTACHMENT POINTS & DISTANCE BETWEEN THEM
Determine the amount of attachment points you need and calculate the distance between them by following the steps outlined below.
Never exceed the maximum distance of 150 cm between each point!
STEP 1
: determine net length (L) of the track
STEP 2
: determine number of attachment points (#p)
STEP 3
: determine distance between attachment points
When connecting two rails with a coupler, always place an extra suspension point within 5 cm of the coupler!
(
𝑳
𝟏, 𝟓
) + 𝟏 = #𝒑
𝑳
(#𝒑 − 𝟏)
= 𝒅𝒊𝒔𝒕𝒂𝒏𝒄𝒆 𝒃𝒆𝒕𝒘𝒆𝒆𝒏 𝒑𝒐𝒊𝒏𝒕𝒔
𝑳 = 𝒕𝒐𝒕𝒂𝒍 𝒕𝒓𝒂𝒄𝒌 𝒍𝒆𝒏𝒈𝒕𝒉 − (𝑨 + 𝑩)