10
DMX-protocol
RGB&D
Mode
Channel 1 – Red
0-255
Gradual adjustment Red from 0 – 100%
Channel 2 – Green
0-255
Gradual adjustment Green from 0 – 100%
Channel 3 – Blue
0-255
Gradual adjustment Blue from 0 – 100%
Channel 4 – Dimmer intensity
0-255
From black to brightest
C&B
Mode
Channel 1 – Color Select
0-255
Color Select
Channel 2 – Dimmer intensity
0-255
From black to brightest
Maintenance
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
1.
All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
2.
There may not be any deformations on housings, fixations and installation spots.
3.
Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
4.
The electric power supply cables must not show any damages or material fatigue.
The Showtec
TriFlood
requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the light-output will be significantly reduced.
Disconnect the mains power supply, and then
wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and a soft
cloth. Do not use alcohol or solvents.
The front glass will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly.
Please clean internal components once a year with a light brush and vacuum cleaner.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying
electric power.